Predictable Heating and Positive MRI Contrast from a Mesoporous Silica-Coated Iron Oxide Nanoparticle
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Iron oxide nanoparticles have great potential as diagnostic and therapeutic agents in cancer and other diseases; however, biological aggregation severely limits their function in vivo. Aggregates can cause poor biodistribution, reduced heating capability, and can confound their visualization and quantification by magnetic resonance imaging (MRI). Herein, we demonstrate that the incorporation of a functionalized mesoporous silica shell can prevent aggregation and enable the practical use of high-heating, high-contrast iron oxide nanoparticles in vitro and in vivo. Unmodified and mesoporous silica-coated iron oxide nanoparticles were characterized in biologically relevant environments including phosphate buffered saline, simulated body fluid, whole mouse blood, lymph node carcinoma of prostate (LNCaP) cells, and after direct injection into LNCaP prostate cancer tumors in nude mice. Once coated, iron oxide nanoparticles maintained colloidal stability along with high heating and relaxivity behaviors (SARFe = 204 W/g Fe at 190 kHz and 20 kA/m and r1 = 6.9 mM(-1) s(-1) at 1.4 T). Colloidal stability and minimal nonspecific cell uptake allowed for effective heating in salt and agarose suspensions and strong signal enhancement in MR imaging in vivo. These results show that (1) aggregation can lower the heating and imaging performance of magnetic nanoparticles and (2) a coating of functionalized mesoporous silica can mitigate this issue, potentially improving clinical planning and practical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3
Kokubo, T., Kushitani, H., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240607 · Cited by 3,836
Oh, J. K., & Park, J. M. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.08.005 · Cited by 427
Nanoparticle toxicity by the gastrointestinal route: evidence and knowledge gaps
Bergin, I. L., & Witzmann, F. A. (2013) · International Journal of Biomedical Nanoscience and Nanotechnology · doi:10.1504/ijbnn.2013.054515 · Cited by 412
Magnetic nanoparticle hyperthermia enhancement of cisplatin chemotherapy cancer treatment
Petryk, A. A., Giustini, A. J., Gottesman, R. E., Kaufman, P. A., & Hoopes, P. J. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.825014 · Cited by 72
Cited by
Synthetic amorphous silica nanoparticles: toxicity, biomedical and environmental implications
Croissant, J. G., Butler, K. S., Zink, J. I., & Brinker, C. J. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0230-0 · Cited by 424
Nanomaterials for Nanotheranostics: Tuning Their Properties According to Disease Needs
Wong, X. Y., Sena-Torralba, A., Álvarez-Diduk, R., Muthoosamy, K., & Merkoçi, A. (2020) · ACS Nano · doi:10.1021/acsnano.9b08133 · Cited by 363
Israel, L. L., Galstyan, A., Holler, E., & Ljubimova, J. Y. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.01.009 · Cited by 337
Improved tissue cryopreservation using inductive heating of magnetic nanoparticles
Manuchehrabadi, N., Gao, Z., Zhang, J., Ring, H. L., Shao, Q., Liu, F., McDermott, M., Fok, A., Rabin, Y., Brockbank, K. G. M., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aah4586 · Cited by 305
Self-citationMagnetic Nanoparticles as MRI Contrast Agents
Avasthi, A., Caro, C., Pozo-Torres, E., Leal, M. P., & García-Martín, M. L. (2020) · Topics in Current Chemistry · doi:10.1007/s41061-020-00302-w · Cited by 253
Metadata
- Authors
- Hurley, K. R., Ring, H. L., Etheridge, M., Zhang, J., Gao, Z., Shao, Q., Klein, N. D., Szlag, V. M., Chung, C., Reineke, T. M., Garwood, M., Bischof, J. C., & Haynes, C. L.
- Venue
- Molecular Pharmaceutics
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-04-04
- Volume
- 13
- Issue
- 7
- Pages
- 2172-2183
- ISSN
- 1543-8384 (ISSN-L)
- 1543-8392
- OpenAlex
- W2302344606
- Cited by
- 94
- References
- 4
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.