Magnesium-Based Micromotors as Hydrogen Generators for Precise Rheumatoid Arthritis Therapy
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Hydrogen therapy is an emerging and highly promising strategy for the treatment of inflammation-related diseases. However, nonpolarity and low solubility of hydrogen under the physiological conditions results in a limited therapeutic effect. Herein, we develop a biocompatible magnesium micromotor coated with hyaluronic acid as a hydrogen generator for precise rheumatoid arthritis management. The hydrogen bubbles generated locally not only function as a propellant for the motion but also function as the active ingredient for reactive oxygen species (ROS) and inflammation scavenging. Under ultrasound guidance, the micromotors are injected intra-articularly, and the dynamics of the micromotors can be visualized. By scavenging ROS and inflammation via active hydrogen, the oxidative stress is relieved and the levels of inflammation cytokines are reduced by our micromotors, showing prominent therapeutic efficacy in ameliorating joint damage and suppressing the overall arthritis severity toward a collagen-induced arthritis rat model. Therefore, our micromotors show great potential for the therapy of rheumatoid arthritis and further clinical transformation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smolen, J. S., Aletaha, D., & McInnes, I. B. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30173-8 · Cited by 4,870
Hydrogen acts as a therapeutic antioxidant by selectively reducing cytotoxic oxygen radicals
Ohsawa, I., Ishikawa, M., Takahashi, K., Watanabe, M., Nishimaki, K., Yamagata, K., Katsura, K.-I., Katayama, Y., Asoh, S., & Ohta, S. (2007) · Nature Medicine · doi:10.1038/nm1577 · Cited by 2,560
Accelerating Medicines Partnership Rheumatoid Arthritis and Systemic Lupus Erythematosus (AMP RA/SLE) Consortium, Zhang, F., Wei, K., Slowikowski, K., Fonseka, C. Y., Rao, D. A., Kelly, S., Goodman, S. M., Tabechian, D., Hughes, L. B., et al. (2019) · Nature Immunology · doi:10.1038/s41590-019-0378-1 · Cited by 1,367
Immunopathogenesis of Rheumatoid Arthritis
Firestein, G. S., & McInnes, I. B. (2017) · Immunity · doi:10.1016/j.immuni.2017.02.006 · Cited by 1,301
Zhang, Q., Dehaini, D., Zhang, Y., Zhou, J., Chen, X., Zhang, L., Fang, R. H., Gao, W., & Zhang, L. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0254-4 · Cited by 958
Nanomagnetic encoding of shape-morphing micromachines
Cui, J., Huang, T.-Y., Luo, Z., Testa, P., Gu, H., Chen, X.-Z., Nelson, B. J., & Heyderman, L. J. (2019) · Nature · doi:10.1038/s41586-019-1713-2 · Cited by 474
Wu, Z., Li, L., Yang, Y., Hu, P., Li, Y., Yang, S.-Y., Wang, L. V., & Gao, W. (2019) · Science Robotics · doi:10.1126/scirobotics.aax0613 · Cited by 466
Self-citationSeawater-driven magnesium based Janus micromotors for environmental remediation
Gao, W., Feng, X., Pei, A., Gu, Y., Li, J., & Wang, J. (2013) · Nanoscale · doi:10.1039/c3nr01458d · Cited by 387
Self‐Propelled Polymer‐Based Multilayer Nanorockets for Transportation and Drug Release
Wu, Z., Wu, Y., He, W., Lin, X., Sun, J., & He, Q. Z. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201301643 · Cited by 375
Medical micro/nanorobots in complex media
Wu, Z., Chen, Y., Mukasa, D., Pak, O. S., & Gao, W. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00309c · Cited by 358
Cited by
Yang, N., Gong, F., Liu, B., Hao, Y., Chao, Y., Lei, H., Yang, X., Gong, Y., Wang, X., Liu, Z., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-29938-6 · Cited by 196
Zhou, H., He, Z., Cao, Y., Chu, L., Liang, B., Yu, K., & Deng, Z. (2024) · Theranostics · doi:10.7150/thno.97412 · Cited by 115
Radicals Scavenging MOFs Enabling Targeting Delivery of siRNA for Rheumatoid Arthritis Therapy
Guo, L., Zhong, S., Liu, P., Guo, M., Ding, J., & Zhou, W. (2022) · Small · doi:10.1002/smll.202202604 · Cited by 103
Metadata
- Authors
- Xu, C., Wang, S., Wang, H., Liu, K., Zhang, S., Chen, B., Liu, H., Tong, F., Peng, F., Tu, Y., & Li, Y.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-02-24
- Volume
- 21
- Issue
- 5
- Pages
- 1982-1991
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W3133248403
- Cited by
- 184
- References
- 59
- FWCI
- 22.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnesium-Based Micromotors as Hydrogen Generators for Precise Rheumatoid Arthritis Therapy. https://app.cochat.ai/papers/10.1021/acs.nanolett.0c04438
- The paper
- Xu, C., Wang, S., Wang, H., Liu, K., Zhang, S., Chen, B., Liu, H., Tong, F., Peng, F., Tu, Y., & Li, Y. (2021). Magnesium-Based Micromotors as Hydrogen Generators for Precise Rheumatoid Arthritis Therapy. Nano Letters. https://doi.org/10.1021/acs.nanolett.0c04438
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.