The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays
Open accessAbstract
Rapid, simple, and cost-effective diagnostics are needed to improve healthcare at the point of care (POC). However, the most widely used POC diagnostic, the lateral flow immunoassay (LFA), is ∼1000-times less sensitive and has a smaller analytical range than laboratory tests, requiring a confirmatory test to establish truly negative results. Here, a rational and systematic strategy is used to design the LFA contrast label (i.e., gold nanoparticles) to improve the analytical sensitivity, analytical detection range, and antigen quantification of LFAs. Specifically, we discovered that the size (30, 60, or 100 nm) of the gold nanoparticles is a main contributor to the LFA analytical performance through both the degree of receptor interaction and the ultimate visual or thermal contrast signals. Using the optimal LFA design, we demonstrated the ability to improve the analytical sensitivity by 256-fold and expand the analytical detection range from 3 log 10 to 6 log 10 for diagnosing patients with inflammatory conditions by measuring C-reactive protein. This work demonstrates that, with appropriate design of the contrast label, a simple and commonly used diagnostic technology can compete with more expensive state-of-the-art laboratory tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ridker, P. M., Hennekens, C. H., Buring, J. E., & Rifai, N. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003233421202 · Cited by 5,850
Cited by
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Self-citationCai, G., Yu, Z., Tong, P., & Tang, D. (2019) · Nanoscale · doi:10.1039/c9nr05797h · Cited by 339
Wang, X., Xiong, E., Tian, T., Cheng, M., Lin, W., Wang, H., Zhang, G., Sun, J., & Zhou, X. (2020) · ACS Nano · doi:10.1021/acsnano.0c00022 · Cited by 326
Lateral flow test engineering and lessons learned from COVID-19
Budd, J., Miller, B. S., Weckman, N. E., Cherkaoui, D., Huang, D., Decruz, A. T., Fongwen, N., Han, G.-R., Broto, M., Estcourt, C. S., et al. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00007-3 · Cited by 308
Metadata
- Authors
- Zhan, L., Guo, S.-Z., Song, F., Gong, Y., Xu, F., Boulware, D. R., McAlpine, M. C., Chan, W. C. W., & Bischof, J. C.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-15
- Volume
- 17
- Issue
- 12
- Pages
- 7207-7212
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2767987683
- Cited by
- 229
- References
- 1
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays. https://app.cochat.ai/papers/10.1021/acs.nanolett.7b02302
- The paper
- Zhan, L., Guo, S.-Z., Song, F., Gong, Y., Xu, F., Boulware, D. R., McAlpine, M. C., Chan, W. C. W., & Bischof, J. C. (2017). The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays. Nano Letters. https://doi.org/10.1021/acs.nanolett.7b02302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.