CoChat

Rapid Sequential in Situ Multiplexing with DNA Exchange Imaging in Neuronal Cells and Tissues

Open access
Wang, Yu, Woehrstein, Johannes B., Donoghue, Noah, Dai, Mingjie, Avendaño, Maier S., Schackmann, Ron C. J., Zoeller, Jason J., Wang, Shan Shan H., Tillberg, Paul W., Park, Demian, Lapan, Sylvain W., Boyden, Edward S., Brugge, Joan S., Kaeser, Pascal S., Church, George M., Agasti, Sarit S., Jungmann, Ralf, Yin, Peng · 2017 · Nano Letters
Cited by 149

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Abstract To decipher the molecular mechanism of biological function, it is critical to map the molecular composition of individual cells in the context of their biological environment in situ . Immunofluorescence (IF) provides specific labeling for molecular profiling. However, conventional IF methods have finite multiplexing capabilities due to spectral overlap of the fluorophores. Various sequential imaging methods have been developed to circumvent this spectral limit, but are not widely adopted due to the common limitation of requiring multi-rounds of slow (typically over 2 hours at room temperature to overnight at 4 °C in practice) immunostaining. DNA-Exchange-Imaging is a practical platform for rapid in situ spectrally-unlimited multiplexing. This technique overcomes speed restrictions by allowing for single-step immunostaining with DNA-barcoded antibodies, followed by rapid (less than 10 minutes) buffer exchange of fluorophore-bearing DNA imager strands. By eliminating the need for multiple rounds of immunostaining, DEI enables rapid spectrally unlimited sequential imaging. The programmability of DNA-Exchange-Imaging allows us to further adapt it to diverse microscopy platforms (with Exchange-Confocal, Exchange-SIM, Exchange-STED, and Exchange-PAINT demonstrated here), achieving highly multiplexed in situ protein visualization in diverse samples (including neuronal and tumor cells as well as fresh-frozen or paraffin-embedded tissue sections) and at multiple desired resolution scales (from ~300 nm down to sub-20-nm). Validation highlights include 8-target imaging using single-channel Exchange-Confocal in tens of micron thick retina tissue sections in 2-3 hours (as compared to days required in principle by previous methods using comparable equipment), and 8-target super-resolution imaging with ~20 nm resolution using Exchange-PAINT in primary neurons. These results collectively suggest DNA-Exchange as a versatile, practical platform for rapid, highly multiplexed in situ imaging, potentially enabling new applications ranging from basic science, to drug discovery, and to clinical pathology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.nanolett.7b02716

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 149

Metadata

Authors
Wang, Y., Woehrstein, J. B., Donoghue, N., Dai, M., Avendaño, M. S., Schackmann, R. C. J., Zoeller, J. J., Wang, S. S. H., Tillberg, P. W., Park, D., Lapan, S. W., Boyden, E. S., Brugge, J. S., Kaeser, P. S., Church, G. M., Agasti, S. S., Jungmann, R., & Yin, P.
Venue
Nano Letters
Published
2017-10-02
Volume
17
Issue
10
Pages
6131-6139
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2759011314
Cited by
149
References
9
FWCI
8.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.