The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hydrogen Sulfide-Activatable Second Near-Infrared Fluorescent Nanoassemblies for Targeted Photothermal Cancer Therapy
Abstract
Near-infrared (NIR)-II fluorescence agents hold great promise for deep-tissue photothermal therapy (PTT) of cancers, which nevertheless remains restricted by the inherent nonspecificity and toxicity of PTT. In response to this challenge, we herein develop a hydrogen sulfide (H 2 S)-activatable nanostructured photothermal agent (Nano-PT) for site-specific NIR-II fluorescence-guided PTT of colorectal cancer (CRC). Our in vivo studies reveal that this theranostic Nano-PT probe is specifically activated in H 2 S-rich CRC tissues, whereas it is nonfunctional in normal tissues. Activation of Nano-PT not only emits NIR-II fluorescence with deeper tissue penetration ability than conventional fluorescent probes but also generates high NIR absorption resulting in efficient photothermal conversion under NIR laser irradiation. Importantly, we establish NIR-II imaging-guided PTT of CRC by applying the Nano-PT agent in tumor-bearing mice, which results in complete tumor regression with minimal nonspecific damages. Our studies thus shed light on the development of cancer biomarker-activated PTT for precision medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Cited by
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Design of superior phototheranostic agents guided by Jablonski diagrams
Feng, G., Zhang, G.-Q., & Ding, D. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00671h · Cited by 783
Theranostic Fluorescent Probes
Sharma, A., Verwilst, P., Li, M., Ma, D., Singh, N., Yoo, J., Kim, Y., Yang, Y., Zhu, J.-H., Huang, H., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00778 · Cited by 499
Semiconducting Polymer Nanomaterials as Near-Infrared Photoactivatable Protherapeutics for Cancer
Li, J., & Pu, K. (2020) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00569 · Cited by 412
Hemicyanine‐Based Near‐Infrared Activatable Probes for Imaging and Diagnosis of Diseases
Zeng, Z., Liew, S. S., Wei, X., & Pu, K. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202107877 · Cited by 359
Metadata
- Authors
- Shi, B., Yan, Q., Tang, J., Xin, K., Zhang, J., Zhu, Y., Xu, G., Wang, R., Chen, J., Gao, W., Zhu, T., Shi, J., Fan, C., Zhao, C., & Tian, H.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-09-21
- Volume
- 18
- Issue
- 10
- Pages
- 6411-6416
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2891587274
- Cited by
- 185
- References
- 1
- FWCI
- 9.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydrogen Sulfide-Activatable Second Near-Infrared Fluorescent Nanoassemblies for Targeted Photothermal Cancer Therapy. https://app.cochat.ai/papers/10.1021/acs.nanolett.8b02767
- The paper
- Shi, B., Yan, Q., Tang, J., Xin, K., Zhang, J., Zhu, Y., Xu, G., Wang, R., Chen, J., Gao, W., Zhu, T., Shi, J., Fan, C., Zhao, C., & Tian, H. (2018). Hydrogen Sulfide-Activatable Second Near-Infrared Fluorescent Nanoassemblies for Targeted Photothermal Cancer Therapy. Nano Letters. https://doi.org/10.1021/acs.nanolett.8b02767
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.