The DOI matches its Crossref record.
Tumor Microenvironment-Responsive Cu2(OH)PO4 Nanocrystals for Selective and Controllable Radiosentization via the X-ray-Triggered Fenton-like Reaction
Abstract
Traditional radiotherapy can induce injury to the normal tissue around the tumor, so the development of novel radiosensitizer with high selectivity and controllability that can lead to more effective and reliable radiotherapy is highly desirable. Herein, a new smart radiosensitizer based on Cu 2 (OH)PO 4 nanocrystals that can simultaneously respond to endogenous stimulus (H 2 O 2 ) and exogenous stimulus (X-ray) is reported. First, Cu 2 (OH)PO 4 nanocrystals can generate Cu I sites under X-ray irradiation through X-ray-induced photoelectron transfer process. Then, X-ray-triggered Cu I sites serve as a catalyst for efficiently decomposing overexpressed H 2 O 2 in the tumor microenvironment into highly toxic hydroxyl radical through the Fenton-like reaction, finally inducing apoptosis and necrosis of cancer cells. Meanwhile, this nonspontaneous Fenton-like reaction is greatly limited within normal tissues because of its oxygen-rich condition and insufficient H 2 O 2 relative to tumor tissues. Thus, this strategy can ensure that the process of radiosentization can only be executed within hypoxic tumors but not in normal cells, resulting in the minimum damages to surrounding healthy tissues. As a result, the X-ray-triggered Fenton-like reaction via introducing nontoxic Cu 2 (OH)PO 4 nanocrystals under the dual stimuli provides a more controllable and reliable activation approach to simultaneously enhance the radiotherapeutic efficacy and reduce side effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dong, S., Dong, Y., Jia, T., Liu, S., Liu, J., Yang, D., He, F., Gai, S., Yang, P., & Lin, J. (2020) · Advanced Materials · doi:10.1002/adma.202002439 · Cited by 592
X-ray-activated nanosystems for theranostic applications
Chen, X., Song, J., Chen, X., & Yang, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00921j · Cited by 401
Reactive Oxygen Species‐Regulating Strategies Based on Nanomaterials for Disease Treatment
Zhang, C., Wang, X., Du, J., Gu, Z., & Zhao, Y. (2021) · Advanced Science · doi:10.1002/advs.202002797 · Cited by 401
Self-citationLiu, G., Zhu, J., Guo, H., Sun, A., Chen, P., Xi, L., Huang, W., Song, X., & Dong, X. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201910815 · Cited by 394
Self-citationHu, K., Xie, L., Zhang, Y., Hanyu, M., Yang, Z., Nagatsu, K., Suzuki, H., Ouyang, J., Ji, X., Wei, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16513-0 · Cited by 346
Metadata
- Authors
- Zhang, C., Yan, L., Wang, X., Dong, X., Zhou, R., Gu, Z., & Zhao, Y.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-18
- Volume
- 19
- Issue
- 3
- Pages
- 1749-1757
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2915788568
- Cited by
- 174
- References
- 0
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tumor Microenvironment-Responsive Cu2(OH)PO4 Nanocrystals for Selective and Controllable Radiosentization via the X-ray-Triggered Fenton-like Reaction. https://app.cochat.ai/papers/10.1021/acs.nanolett.8b04763
- The paper
- Zhang, C., Yan, L., Wang, X., Dong, X., Zhou, R., Gu, Z., & Zhao, Y. (2019). Tumor Microenvironment-Responsive Cu2(OH)PO4 Nanocrystals for Selective and Controllable Radiosentization via the X-ray-Triggered Fenton-like Reaction. Nano Letters. https://doi.org/10.1021/acs.nanolett.8b04763
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.