The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Reactive Oxygen Correlated Chemiluminescent Imaging of a Semiconducting Polymer Nanoplatform for Monitoring Chemodynamic Therapy
Abstract
In chemodynamic therapy (CDT), real-time monitoring of reactive oxygen species (ROS) production is critical to reducing the nonspecific damage during CDT and feasibly evaluating the therapeutic response. However, CDT agents that can emit ROS-related signals are rare. Herein, we synthesize a semiconducting polymer nanoplatform (SPN) that can not only produce highly toxic ROS to kill cancer cells but also emit ROS-correlated chemiluminescent signals. Notably, the efficacy of both chemiluminescence and CDT can be significantly enhanced by hemin doping (∼10-fold enhancement for luminescent intensity). Such ROS-dependent chemiluminescence of SPN allows ROS generation within a tumor to be optically monitored during the CDT process. Importantly, SPN establishes an excellent correlation of chemiluminescence intensities with cancer inhibition rates in vitro and in vivo. Thus, our nanoplatform represents the first intelligent strategy that enables chemiluminescence-imaging-monitored CDT, which holds potential in assessing therapeutic responsivity and predicting treatment outcomes in early stages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, C., Cao, F., Ruan, Y., Jia, X., Zhen, W., & Jiang, X. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201903981 · Cited by 411
Walling, C., & Goosen, A. (1973) · Journal of the American Chemical Society · doi:10.1021/ja00790a042 · Cited by 410
Song, G., Chen, Y., Liang, C., Yi, X., Liu, J., Sun, X., Shen, S., Yang, K., & Liu, Z. (2016) · Advanced Materials · doi:10.1002/adma.201602111 · Cited by 394
Self-citation
Cited by
Recent progress of chemodynamic therapy-induced combination cancer therapy
Wang, X., Zhong, X., Liu, Z., & Cheng, L. (2020) · Nano Today · doi:10.1016/j.nantod.2020.100946 · Cited by 711
Chemodynamic Therapy via Fenton and Fenton‐Like Nanomaterials: Strategies and Recent Advances
Jia, C., Guo, Y., & Wu, F. (2022) · Small · doi:10.1002/smll.202103868 · Cited by 685
Zhou, Y., Fan, S., Feng, L., Huang, X., & Chen, X. (2021) · Advanced Materials · doi:10.1002/adma.202104223 · Cited by 463
Co–Ferrocene MOF/Glucose Oxidase as Cascade Nanozyme for Effective Tumor Therapy
Fang, C., Deng, Z., Cao, G., Chu, Q., Wu, Y., Li, X., Peng, X., & Han, G. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910085 · Cited by 423
Jiang, L., He, C.-H., Chen, H.-Y., Xi, C.-Y., Fodjo, E. K., Zhou, Z.-R., Qian, R.-C., Li, D.-W., & Hafez, M. E. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c02233 · Cited by 54
Metadata
- Authors
- Wang, Y., Shi, L., Ye, Z., Guan, K., Teng, L., Wu, J., Yin, X., Song, G., & Zhang, X.-B.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-11-28
- Volume
- 20
- Issue
- 1
- Pages
- 176-183
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2990852606
- Cited by
- 159
- References
- 3
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reactive Oxygen Correlated Chemiluminescent Imaging of a Semiconducting Polymer Nanoplatform for Monitoring Chemodynamic Therapy. https://app.cochat.ai/papers/10.1021/acs.nanolett.9b03556
- The paper
- Wang, Y., Shi, L., Ye, Z., Guan, K., Teng, L., Wu, J., Yin, X., Song, G., & Zhang, X.-B. (2020). Reactive Oxygen Correlated Chemiluminescent Imaging of a Semiconducting Polymer Nanoplatform for Monitoring Chemodynamic Therapy. Nano Letters. https://doi.org/10.1021/acs.nanolett.9b03556
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.