The DOI matches its Crossref record; 120 of the 120 references it cites were found in a registry or an index.
Flexible Electrochemical Biosensors for Health Monitoring
Abstract
Flexible electrochemical biosensors play an important role in disease diagnosis and healthcare management. Currently, the applications of flexible electrochemical biosensors are mainly for the detection of biomarkers in various body fluids. Moreover, the flexible sensors can be used as wearable devices for in situ detection and long-term monitoring of target analytes. In this review, the representative electrochemical biosensors including amperometric and potentiometric biosensors prepared on flexible substrates and their major applications are introduced. Then, we focus on transistor-based flexible biosensors that show high sensitivity and low detection limits, which are suitable for multiplexing and high-throughput sensing applications. The current challenges and outlook for the development of flexible biosensors are further discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition to conventional electrochemical biosensing techniques, the transistor-based approach, including field-effect transistors (FET) and organic electrochemical transistors (OECT) also show great promise owing to their ability for in situ amplification of the detected signal.[235,236]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [235]
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Wang, C., Dong, H., Hu, W., Liu, Y., & Zhu, D. (2012) · Chemical Reviews · doi:10.1021/cr100380z · Cited by 3,605
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Approaching ballistic transport in suspended graphene
Du, X., Skachko, I., Barker, A., & Andrei, E. Y. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.199 · Cited by 3,258
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Organic Field-Effect Transistors
Horowitz, G. (1998) · Advanced Materials · doi:10.1002/(sici)1521-4095(199803)10:5<389::aid-adma388>3.0.co;2-9 · Cited by 2,455
Organic Field-Effect Transistors
Horowitz, G. (1998) · Advanced Materials · doi:10.1002/(sici)1521-4095(199803)10:5<365::aid-adma365>3.0.co;2-u · Cited by 2,419
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
Fiber‐Based Wearable Electronics: A Review of Materials, Fabrication, Devices, and Applications
Zeng, W., Shu, L., Li, Q., Chen, S., Wang, F., & Tao, X. (2014) · Advanced Materials · doi:10.1002/adma.201400633 · Cited by 2,019
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Advances in Ionic Thermoelectrics: From Materials to Devices
Sun, S., Li, M., Shi, X., & Chen, Z. (2023) · Advanced Energy Materials · doi:10.1002/aenm.202203692 · Cited by 237
Gao, Q., Agarwal, S., Greiner, A., & Zhang, T. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101139 · Cited by 175
Flexible and Stretchable Electrochemical Sensors for Biological Monitoring
Zhao, Y., Jin, K., Li, J., Sheng, K., Huang, W., & Liu, Y. (2023) · Advanced Materials · doi:10.1002/adma.202305917 · Cited by 171
Metadata
- Authors
- Yang, A., & Yan, F.
- Affiliations
- Hong Kong Polytechnic University (HK)
- Corresponding author
- Yan, Feng
- Venue
- ACS Applied Electronic Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-08-25
- Volume
- 3
- Issue
- 1
- Pages
- 53-67
- ISSN
- 2637-6113 (ISSN-L)
- OpenAlex
- W3081483134
- Cited by
- 122
- References
- 120
- Citations by year
- 2026: 9 · 2025: 19 · 2024: 20 · 2023: 28 · 2022: 30 · 2021: 15 · 2020: 1
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- ACS Applied Electronic Materials (publishedVersion)
- Funders
- Innovation and Technology Commission (MRP/040/18X)
- Hong Kong Polytechnic University (G-UAF1, G-YBJ0)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- wearable devices, health monitoring, amperometric biosensor, potentiometric biosensor, flexible substrates, biomarker detection, body fluid analysis, multiplexed sensing, disease diagnosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Electrochemical Biosensors for Health Monitoring. https://app.cochat.ai/papers/10.1021/acsaelm.0c00534
- The paper
- Yang, A., & Yan, F. (2021). Flexible Electrochemical Biosensors for Health Monitoring. ACS Applied Electronic Materials. https://doi.org/10.1021/acsaelm.0c00534
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.