The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Conductive Anion-Exchange Membranes Based on Cross-Linked Poly(norbornene): Vinyl Addition Polymerization
Abstract
Cross-linked (XL) anion-exchange membranes (AEMs) synthesized by vinyl addition polymerization of norbornene were prepared for use in anion-exchange membrane electrochemical devices, including fuel cells and electrolyzers. Tetrablock copolymers composed of an all-hydrocarbon backbone with a very high ion-exchange capacity (IEC), 3.46 mequiv/g, were synthesized. Light cross-linking was found to be adequate for providing critical control over unwanted water uptake. This enabled use of very high IEC membranes. Without light cross-linking, the unwanted water uptake would cause swelling and softening of the membrane. The best performing membrane had no significant drop in ionic conductivity over 1000 h of aging in 1 M NaOH at 80 °C and a record high ionic conductivity of 198 mS/cm at 80 °C (for a chemically stable AEM). The number of bound and free water molecules per ion pair is described along with ion mobility comparisons to previous materials. The membranes are suitable for electrochemical devices and were used in AEM fuel cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anion-exchange membranes in electrochemical energy systems
Varcoe, J. R., Atanassov, P., Dekel, D. R., Herring, A. M., Hickner, M. A., Kohl, P. A., Kucernak, A. R., Mustain, W. E., Nijmeijer, K., Scott, K., et al. (2014) · Energy Environ. Sci. · doi:10.1039/c4ee01303d · Cited by 2,051
Self-citation
Cited by
Anion-Exchange Membrane Water Electrolyzers
Du, N., Roy, C., Peach, R., Turnbull, M., Thiele, S., & Bock, C. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00854 · Cited by 1,075
Electrocatalysis in Alkaline Media and Alkaline Membrane-Based Energy Technologies
Yang, Y., Peltier, C. R., Zeng, R., Schimmenti, R., Li, Q., Huang, X., Yan, Z., Potsi, G., Selhorst, R., Lu, X., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00331 · Cited by 544
Anion exchange polyelectrolytes for membranes and ionomers
Chen, N., & Lee, Y. M. (2021) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2020.101345 · Cited by 445
Alkaline-stable anion exchange membranes: A review of synthetic approaches
You, W., Noonan, K. J. T., & Coates, G. W. (2020) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.101177 · Cited by 389
Separators and Membranes for Advanced Alkaline Water Electrolysis
Henkensmeier, D., Cho, W.-C., Jannasch, P., Stojadinovic, J., Li, Q., Aili, D., & Jensen, J. O. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00694 · Cited by 360
Ul Hassan, N., Mandal, M., Huang, G., Firouzjaie, H. A., Kohl, P. A., & Mustain, W. E. (2020) · Advanced Energy Materials · doi:10.1002/aenm.202001986 · Cited by 291
Self-citationAnion Exchange Membrane Water Electrolysis Based on Nickel Ferrite Catalysts
Caprì, A., Gatto, I., Lo Vecchio, C., Trocino, S., Carbone, A., & Baglio, V. (2023) · ChemElectroChem · doi:10.1002/celc.202201056 · Cited by 57
Metadata
- Authors
- Mandal, M., Huang, G., & Kohl, P. A.
- Venue
- ACS Applied Energy Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-03-20
- Volume
- 2
- Issue
- 4
- Pages
- 2447-2457
- ISSN
- 2574-0962 (ISSN-L)
- OpenAlex
- W2923423162
- Cited by
- 173
- References
- 1
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.