Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Highly Conductive Anion-Exchange Membranes Based on Cross-Linked Poly(norbornene): Vinyl Addition Polymerization

Mandal, Mrinmay, Huang, Garrett, Kohl, Paul A.·2019·ACS Applied Energy Materials

Abstract

Cross-linked (XL) anion-exchange membranes (AEMs) synthesized by vinyl addition polymerization of norbornene were prepared for use in anion-exchange membrane electrochemical devices, including fuel cells and electrolyzers. Tetrablock copolymers composed of an all-hydrocarbon backbone with a very high ion-exchange capacity (IEC), 3.46 mequiv/g, were synthesized. Light cross-linking was found to be adequate for providing critical control over unwanted water uptake. This enabled use of very high IEC membranes. Without light cross-linking, the unwanted water uptake would cause swelling and softening of the membrane. The best performing membrane had no significant drop in ionic conductivity over 1000 h of aging in 1 M NaOH at 80 °C and a record high ionic conductivity of 198 mS/cm at 80 °C (for a chemically stable AEM). The number of bound and free water molecules per ion pair is described along with ion mobility comparisons to previous materials. The membranes are suitable for electrochemical devices and were used in AEM fuel cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsaem.8b02051

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 173

Metadata

Authors
Mandal, M., Huang, G., & Kohl, P. A.
Venue
ACS Applied Energy Materials
Published
2019-03-20
Volume
2
Issue
4
Pages
2447-2457
ISSN
2574-0962 (ISSN-L)
OpenAlex
W2923423162
Cited by
173
References
1
FWCI
6.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.