The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Flexible Piezoelectric Pressure Tactile Sensor Based on Electrospun BaTiO3/Poly(vinylidene fluoride) Nanocomposite Membrane
Abstract
Poly(vinylidene fluoride) (PVDF)-based piezoelectric materials are promising candidates for sensors, transducers, and actuators, due to several distinctive characteristics such as good flexibility, easy processability, and high mechanical resistance. In the present work, PVDF-based nanocomposites loaded with BaTiO 3 nanoparticles (NPs) of various weight fractions were prepared by the electrospinning technique and used for the fabrication of a flexible piezoelectric pressure tactile sensor (PPTS). The addition (5, 10, and 20 wt %) of piezoelectric BaTiO 3 NPs improves the piezoelectric performance, especially the β phase crystals of PVDF/BaTiO 3 (10 wt %) nanocomposites that can reach 91.0%. In addition, the mechanical strength of PVDF/BaTiO 3 nanocomposites is up to 26.7 MPa, which is an increase of 66% compared to neat PVDF. It should be emphasized that the elongation at break continuously increases from 71% to 153% with increasing BaTiO 3 NPs. More importantly, the PPTS (piezoelectric pressure tactile sensor) with the combination of electrospun PVDF/BaTiO 3 nanocomposite membranes and polydimethylsiloxane (PDMS) displays excellent flexibility and linear response to external mechanical force. The flexible PPTS devices capable of detecting different music sounds have potential uses in wide fields, such as voice recognition, speech therapy, and ultrasound imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electroactive phases of poly(vinylidene fluoride): Determination, processing and applications
Martins, P., Lopes, A. C., & Lanceros-Mendez, S. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.07.006 · Cited by 3,494
Lovinger, A. J. (1983) · Science · doi:10.1126/science.220.4602.1115 · Cited by 1,939
A Review of Power Harvesting from Vibration Using Piezoelectric Materials
Sodano, H. A., Inman, D. J., & Park, G. (2004) · The Shock and Vibration Digest · doi:10.1177/0583102404043275 · Cited by 1,361
Persano, L., Dagdeviren, C., Su, Y., Zhang, Y., Girardo, S., Pisignano, D., Huang, Y., & Rogers, J. A. (2013) · Nature Communications · doi:10.1038/ncomms2639 · Cited by 1,271
Advances in three-dimensional nanofibrous macrostructures via electrospinning
Sun, B., Long, Y. Z., Zhang, H. D., Li, M. M., Duvail, J. L., Jiang, X. Y., & Yin, H. L. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.06.002 · Cited by 792
α to β Phase Transformation and Microestructural Changes of PVDF Films Induced by Uniaxial Stretch
Sencadas, V., Gregorio, R., & Lanceros-Méndez, S. (2009) · Journal of Macromolecular Science, Part B · doi:10.1080/00222340902837527 · Cited by 607
Highly Stretchable Piezoelectric‐Pyroelectric Hybrid Nanogenerator
Lee, J., Lee, K. Y., Gupta, M. K., Kim, T. Y., Lee, D., Oh, J., Ryu, C., Yoo, W. J., Kang, C., Yoon, S., et al. (2014) · Advanced Materials · doi:10.1002/adma.201303570 · Cited by 550
Recent progress in flexible–wearable solar cells for self-powered electronic devices
Hashemi, S. A., Ramakrishna, S., & Aberle, A. G. (2020) · Energy & Environmental Science · doi:10.1039/c9ee03046h · Cited by 527
Piezoelectric nanofibers for energy scavenging applications
Chang, J., Dommer, M., Chang, C., & Lin, L. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.02.003 · Cited by 444
Guan, X., Xu, B., & Gong, J. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.104516 · Cited by 359
Cited by
Piezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 434
Wearable Pressure Sensors Based on MXene/Tissue Papers for Wireless Human Health Monitoring
Yang, L., Wang, H., Yuan, W., Li, Y., Gao, P., Tiwari, N., Chen, X., Wang, Z., Niu, G., & Cheng, H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c22001 · Cited by 283
Yu, J., Xian, S., Zhang, Z., Hou, X., He, J., Mu, J., Geng, W., Qiao, X., Zhang, L., & Chou, X. (2023) · Nano Research · doi:10.1007/s12274-022-5084-x · Cited by 143
Liu, X., Tong, J., Wang, J., Lu, S., Yang, D., Li, H., Liu, C., & Song, Y. (2023) · Journal of Materials Chemistry C · doi:10.1039/d2tc05291a · Cited by 104
Sharma, A., Ansari, M. Z., & Cho, C. (2022) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2022.113934 · Cited by 95
Li, X., Liu, Y., Ding, Y., Zhang, M., Lin, Z., Hao, Y., Li, Y., & Chang, J. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c01042 · Cited by 79
Kim, D., Yang, Z., Cho, J., Park, D., Kim, D. H., Lee, J., Ryu, S., Kim, S., & Kim, M. (2023) · EcoMat · doi:10.1002/eom2.12384 · Cited by 64
Metadata
- Authors
- Jiang, J., Tu, S., Fu, R., Li, J., Hu, F., Yan, B., Gu, Y., & Chen, S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-07-01
- Volume
- 12
- Issue
- 30
- Pages
- 33989-33998
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3038678644
- Cited by
- 260
- References
- 30
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.