The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Self-Adhesive, Stretchable, Biocompatible, and Conductive Nonvolatile Eutectogels as Wearable Conformal Strain and Pressure Sensors and Biopotential Electrodes for Precise Health Monitoring
Abstract
Conductive stretchable hydrogels and ionogels consisting of ionic liquids can have interesting application as wearable strain and pressure sensors and bioelectrodes due to their soft nature and high conductivity. However, hydrogels have a severe stability problem because of water evaporation, whereas ionogels are not biocompatible or even toxic. Here, we demonstrate self-adhesive, stretchable, nonvolatile, and biocompatible eutectogels that can always form conformal contact to skin even during body movement along with their application as wearable strain and pressure sensors and biopotential electrodes for precise health monitoring. The eutectogels consist of a deep eutectic solvent that has high conductivity, waterborne polyurethane that is an elastomer, and tannic acid that is an adhesive. They can have an elongation at a break of 178%, ionic conductivity of 0.22 mS/cm, and adhesion force of 12.5 N/m to skin. They can be used as conformal strain sensors to accurately monitor joint movement and breath. They can be even used as pressure sensors with a piezoresistive sensitivity of 284.4 kPa –1 to precisely detect subtle physical movements like arterial pulses, which can provide vital cardiovascular information. Moreover, the eutectogels can be used as nonvolatile conformal electrodes to monitor epidermal physiological signals, such as electrocardiogram (ECG) and electromyogram (EMG).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep eutectic solvents: syntheses, properties and applications
Zhang, Q., De Oliveira Vigier, K., Royer, S., & Jérôme, F. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35178a · Cited by 4,899
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Ye, Y., Zhang, Y., Chen, Y., Han, X., & Jiang, F. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003430 · Cited by 826
Cited by
Naturally sourced hydrogels: emerging fundamental materials for next-generation healthcare sensing
Wang, Z., Wei, H., Huang, Y., Wei, Y., & Chen, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00813k · Cited by 392
Self-citation
Metadata
- Authors
- Wang, S., Cheng, H., Yao, B., He, H., Zhang, L., Yue, S., Wang, Z., & Ouyang, J.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-04-26
- Volume
- 13
- Issue
- 17
- Pages
- 20735-20745
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3158293317
- Cited by
- 163
- References
- 4
- FWCI
- 7.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.