Highly Sensitive and Stretchable MXene/CNTs/TPU Composite Strain Sensor with Bilayer Conductive Structure for Human Motion Detection
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The universal application of wearable strain sensors in various situations for human-activity monitoring is considerably limited by the contradiction between high sensitivity and broad working range. There still remains a huge challenge to design sensors featuring simultaneous broad working range and high sensitivity. Herein, a typical bilayer-conductive structure Ti 3 C 2 T x MXene/carbon nanotubes (CNTs)/thermoplastic polyurethane (TPU) composite film was developed by a simple and scalable vacuum filtration process utilizing a porous electrospun thermoplastic polyurethane (TPU) mat as a skeleton. The MXene/CNTs/TPU strain sensor is composed of two parts: a brittle densely stacked MXene upper lamella and a flexible MXene/CNT-decorated fibrous network lower layer. Benefiting from the synergetic effect of the two parts along with hydrogen-bonding interactions between the porous TPU fiber mat and MXene sheets, the MXene/CNTs/TPU strain sensor possesses both a broad working range (up to 330%) and high sensitivity (maximum gauge factor of 2911) as well as superb long-term durability (2600 cycles under the strain of 50%). Finally, the sensor can be successfully employed for human movement monitoring, from tiny facial expressions, respiration, and pulse beat to large-scale finger and elbow bending, demonstrating a promising and attractive application for wearable devices and human–machine interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626
Liu, Q., Chen, J., Li, Y., & Shi, G. (2016) · ACS Nano · doi:10.1021/acsnano.6b03813 · Cited by 609
Cited by
MXenes for wearable pressure sensing: Progress and prospects in human motion detection
Kong, X., Fan, C., Liao, K., Zhang, W., & Xiong, H. (2025) · Alexandria Engineering Journal · doi:10.1016/j.aej.2025.01.086 · Cited by 7
Metadata
- Authors
- Dong, H., Sun, J., Liu, X., Jiang, X., & Lu, S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-03-28
- Volume
- 14
- Issue
- 13
- Pages
- 15504-15516
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W4221028180
- Cited by
- 247
- References
- 3
- FWCI
- 14.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Stretchable MXene/CNTs/TPU Composite Strain Sensor with Bilayer Conductive Structure for Human Motion Detection. https://app.cochat.ai/papers/10.1021/acsami.1c23567
- The paper
- Dong, H., Sun, J., Liu, X., Jiang, X., & Lu, S. (2022). Highly Sensitive and Stretchable MXene/CNTs/TPU Composite Strain Sensor with Bilayer Conductive Structure for Human Motion Detection. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.1c23567
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.