Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record.

Nano-TiO2 Reinforced PEEK/PEI Blends as Biomaterials for Load-Bearing Implant Applications

Díez-Pascual, Ana M., Díez-Vicente, Angel L.·2015·ACS Applied Materials & Interfaces

Abstract

Biocompatible ternary nanocomposites based on poly(ether ether ketone) (PEEK)/poly(ether imide) (PEI) blends reinforced with bioactive titanium dioxide (TiO2) nanoparticles were fabricated via ultrasonication followed by melt-blending. The developed biomaterials were characterized using FT-IR, SEM, XRD, DSC, TGA, and DMA. Further, their water-absorption, tensile, tribological, dielectric, and antibacterial properties were evaluated. PEI acts as a coupling agent, since it can interact both with PEEK via π-π stacking and polar interactions as well as with the nanoparticles through hydrogen bonding, as corroborated by the FT-IR spectra, which resulted in a homogeneous titania dispersion within the biopolymer blend without applying any particle surface treatment or polymer functionalization. A change from promotion to retardation in the crystallization rate of the matrix was found with increasing TiO2 concentration, while its crystalline structure remained unaltered. The nanoparticles stiffened, strengthened, and toughened the matrix simultaneously, and the optimal properties were achieved at 4.0 wt % TiO2. More interesting, the tensile properties were retained after steam sterilization in an autoclave or exposure to a simulated body fluid (SBF). The nanocomposites also displayed reduced water absorption though higher thermal stability, storage modulus, glass transition temperature, dielectric constant, and dielectric loss compared to the control blend. Further, remarkable enhancements in the tribological properties under both SBF and dry environments were attained. The nanoparticles conferred antibacterial action versus Gram-positive and Gram-negative bacteria in the presence and the absence of UV light, and the highest inhibition was attained at 4.0 wt % nanoparticle concentration. These nanocomposites are expected to be used in long-term load-bearing implant applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.5b00210

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Díez-Pascual, A. M., & Díez-Vicente, A. L.
Venue
ACS Applied Materials & Interfaces
Published
2015-02-27
Volume
7
Issue
9
Pages
5561-5573
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2331802868
Cited by
198
References
0
FWCI
5.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nano-TiO2 Reinforced PEEK/PEI Blends as Biomaterials for Load-Bearing Implant Applications. https://app.cochat.ai/papers/10.1021/acsami.5b00210
The paper
Díez-Pascual, A. M., & Díez-Vicente, A. L. (2015). Nano-TiO2 Reinforced PEEK/PEI Blends as Biomaterials for Load-Bearing Implant Applications. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.5b00210

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.