Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Highly Stretchable and Ultrasensitive Strain Sensor Based on Reduced Graphene Oxide Microtubes–Elastomer Composite

Tang, Yongchao, Zhao, Zongbin, Hu, Han, Liu, Yang, Wang, Xuzhen, Zhou, Shanke, Qiu, Jieshan·2015·ACS Applied Materials & Interfaces

Abstract

Strain sensors with excellent flexibility, stretchability, and sensitivity have attracted increasing interests. In this paper, a highly stretchable and ultrasensitive strain sensor based on reduced graphene oxide microtubes-elastomer is fabricated by a template induced assembly and followed a polymer coating process. The sensors can be stretched in excess of 50% of its original length, showing long-term durability and excellent selectivity to a specific strain under various disturbances. The sensitivity of this sensor is as high as 630 of gauge factor under 21.3% applied strain; more importantly, it can be easily modulated to accommodate diverse requirements. Implementation of the device for gauging muscle-induced strain in several biological systems shows reproducibility and different responses in the form of resistance or current change. The developed strain sensors show great application potential in fields of biomechanical systems, communications, and other related areas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.5b09314

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 209

Metadata

Authors
Tang, Y., Zhao, Z., Hu, H., Liu, Y., Wang, X., Zhou, S., & Qiu, J.
Venue
ACS Applied Materials & Interfaces
Published
2015-12-07
Volume
7
Issue
49
Pages
27432-27439
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2264444677
Cited by
209
References
7
FWCI
10.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.