Chitosan-Coated Diatom Silica as Hemostatic Agent for Hemorrhage Control

Feng, Chao, Li, Jing, Wu, Guang Sheng, Mu, Yu Zhi, Kong, Ming, Jiang, Chang Qing, Cheng, Xiao Jie, Liu, Ya, Chen, Xi Guang·2016·ACS Applied Materials & Interfaces

Abstract

Uncontrolled hemorrhage leads to high death risk both in military and civilian trauma. Current hemostatic agents still have various limitations and side effects. In this study, natural diatom silica obtained from diatomite and diatom culture was purified and developed for hemorrhage control. To improve the biocompatibility and hemostatic performance of diatom silica, a series of chitosan-coated diatom (CS-diatom) was developed. The composition of CS-diatom prepared was optimized by in vitro hemocompatibility and blood coagulation evaluation for that prepared with 0.5%, 1%, 3%, and 5% chitosan. The results demonstrated that the CS-diatom prepared with 1% chitosan exhibited favorable biocompatibility (hemolysis ratio < 5%, no cytotoxicity to MEFs), great fluid absorbility (24.39 ± 1.53 times the weight of liquid), and desirable hemostasis effect (351 ± 14.73 s at 5 mg/mL, 248 ± 32.42s at 10 mg/mL). Further blood coagulation mechanism study indicated that CS-diatom could provide an ideal interface to induce erythrocyte absorption and aggregation, along with activating the intrinsic coagulation pathway and thus accelerated blood coagulation. Benefitting from the multiple hemostatic performances, CS-diatom showed the shortest clotting time (98.34 ± 26.54 s) and lowest blood loss (0.31 ± 0.11 g) in rat-tail amputation model compare to diatomite and diatom as well as gauze and commercial QuikClot zeolite. The results evidenced that the CS-diatom was a safe and effective hemostatic agent and provided a new understanding of nonsynthetic mesoporous materials for hemorrhage control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.6b12317

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 202

Metadata

Authors
Feng, C., Li, J., Wu, G. S., Mu, Y. Z., Kong, M., Jiang, C. Q., Cheng, X. J., Liu, Y., & Chen, X. G.
Venue
ACS Applied Materials & Interfaces
Published
2016-12-08
Volume
8
Issue
50
Pages
34234-34243
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2557643060
Cited by
202
References
2
FWCI
10.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Chitosan-Coated Diatom Silica as Hemostatic Agent for Hemorrhage Control. https://app.cochat.ai/papers/10.1021/acsami.6b12317
The paper
Feng, C., Li, J., Wu, G. S., Mu, Y. Z., Kong, M., Jiang, C. Q., Cheng, X. J., Liu, Y., & Chen, X. G. (2016). Chitosan-Coated Diatom Silica as Hemostatic Agent for Hemorrhage Control. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.6b12317

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.