The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Enhanced Corrosion Resistance and Biocompatibility of Magnesium Alloy by Mg–Al-Layered Double Hydroxide
Abstract
Magnesium (Mg) and its alloys have been suggested as revolutionary biodegradable materials. However, fast degradation hinders its clinic application. To improve the corrosion resistance and biocompatibility of Mg–Nd–Zn–Zr alloy (JDBM), magnesium–aluminum-layered double hydroxide (Mg–Al LDH) was successfully introduced into Mg(OH) 2 coating by hydrothermal treatment. The anions in the interlayer of Mg–Al LDH can be replaced by chloride ions, resulting in a relatively low chloride ion concentration near the surface of the coating. The favorable corrosion resistance of the coating was proved by polarization curves and hydrogen collection test. The Mg–Al LDH significantly promoted cell adhesion, migration and proliferation in vitro. In addition, the coating almost fulfilled the request of the clinical application in the hemolysis ratio test. Finally, in vivo results indicated that the coating offered the greatest long-lasting protection from corrosion and triggered the mildest inflammation comparing to the pure Mg(OH) 2 coatings and untreated magnesium alloy. Mg(OH) 2 coating containing Mg–Al LDH in the present study shows a promising application in improving anticorrosion and biocompatibility of Mg alloys, and might act as a platform for a further modification of Mg alloys ascribed to its special layer structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The nitrate-nitrite-nitric oxide pathway in physiology and therapeutics
Lundberg, J. O., Weitzberg, E., & Gladwin, M. T. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2466 · Cited by 2,739
Suchyta, D. J., Handa, H., & Meyerhoff, M. E. (2014) · Molecular Pharmaceutics · doi:10.1021/mp400501c · Cited by 40
Cited by
Layered double hydroxide (LDH) for multi-functionalized corrosion protection of metals: A review
Cao, Y., Zheng, D., Zhang, F., Pan, J., & Lin, C. (2022) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2021.05.078 · Cited by 279
Layered double hydroxide coatings on magnesium alloys: A review
Guo, L., Wu, W., Zhou, Y., Zhang, F., Zeng, R., & Zeng, J. (2018) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2018.03.003 · Cited by 262
Li, B., Gao, P., Zhang, H., Guo, Z., Zheng, Y., & Han, Y. (2018) · Biomaterials Science · doi:10.1039/c8bm00901e · Cited by 80
Zhang, D., Cheng, S., Tan, J., Xie, J., Zhang, Y., Chen, S., Du, H., Qian, S., Qiao, Y., Peng, F., et al. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.01.032 · Cited by 79
Self-citationWang, Z., Liu, B., Yin, B., Zheng, Y., Tian, Y., & Wen, P. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.1066103 · Cited by 30
“8–1, preventing complete coverage of the oxide on its surface (Peng et al., 2016).”
BackgroundSelf-citation
Metadata
- Authors
- Peng, F., Li, H., Wang, D., Tian, P., Tian, Y., Yuan, G., Xu, D., & Liu, X.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-12-16
- Volume
- 8
- Issue
- 51
- Pages
- 35033-35044
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2559797634
- Cited by
- 219
- References
- 2
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Corrosion Resistance and Biocompatibility of Magnesium Alloy by Mg–Al-Layered Double Hydroxide. https://app.cochat.ai/papers/10.1021/acsami.6b12974
- The paper
- Peng, F., Li, H., Wang, D., Tian, P., Tian, Y., Yuan, G., Xu, D., & Liu, X. (2016). Enhanced Corrosion Resistance and Biocompatibility of Magnesium Alloy by Mg–Al-Layered Double Hydroxide. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.6b12974
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.