The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Graphene-Montmorillonite Composite Sponge for Safe and Effective Hemostasis
Abstract
Montmorillonite (MMT) is considered to be the most effective hemostat among natural phyllosilicates. However, there is a barrier against using MMT for the commercial hemostatics because the invaded MMT powders might cause thrombosis in vessel. Until now, it is still a challenge to manage the release of MMT and eliminate its side effect. Herein, we present a graphene-MMT composite sponge (GMCS), synthesized under a hydrothermal reaction, fixing MMT powders into the cross-linked graphene sheets. We demonstrate that only a few embedded MMT can evoke remarkable platelet stimulation at the sponge interface, while maintaining fast plasma absorbency of the innate sponge. In the synergy of the above hemostatic mechanisms, the GMCS can rapidly stop bleeding in approximately 85 s in rabbit artery injury test. More importantly, computed tomography angiography certifies that the GMCS does not cause thrombus or blood clot in vessels. Cytotoxicity assay further highlights its biocompatibility. In-depth analysis proposes that two-dimensional graphene overmatches one-dimensional linear polymers in the composite construction, and dimension transformation of blood distribution plays a crucial role for reinforcing the hemostatic performance. This GMCS hemostat not only opens a new perspective for graphene composite, but also makes a new chance of using clays for trauma therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mid-infrared plasmonic biosensing with graphene
Rodrigo, D., Limaj, O., Janner, D., Etezadi, D., García de Abajo, F. J., Pruneri, V., & Altug, H. (2015) · Science · doi:10.1126/science.aab2051 · Cited by 1,462
Cited by
Zhao, X., Guo, B., Wu, H., Liang, Y., & Ma, P. X. (2018) · Nature Communications · doi:10.1038/s41467-018-04998-9 · Cited by 1,161
Self-citationHaemostatic materials for wound healing applications
Guo, B., Dong, R., Liang, Y., & Li, M. (2021) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00323-z · Cited by 992
Self-citationMultifunctional hydrogels for wound healing: Special focus on biomacromolecular based hydrogels
Asadi, N., Pazoki-Toroudi, H., Del Bakhshayesh, A. R., Akbarzadeh, A., Davaran, S., & Annabi, N. (2021) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2020.12.202 · Cited by 312
Engineered Hemostatic Biomaterials for Sealing Wounds
Montazerian, H., Davoodi, E., Baidya, A., Baghdasarian, S., Sarikhani, E., Meyer, C. E., Haghniaz, R., Badv, M., Annabi, N., Khademhosseini, A., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c01015 · Cited by 291
A tightly-bonded and flexible mesoporous zeolite-cotton hybrid hemostat
Yu, L., Shang, X., Chen, H., Xiao, L., Zhu, Y., & Fan, J. (2019) · Nature Communications · doi:10.1038/s41467-019-09849-9 · Cited by 254
Metadata
- Authors
- Li, G., Quan, K., Liang, Y., Li, T., Yuan, Q., Tao, L., Xie, Q., & Wang, X.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-12-16
- Volume
- 8
- Issue
- 51
- Pages
- 35071-35080
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2560689490
- Cited by
- 188
- References
- 1
- FWCI
- 10.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.