Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 252

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Flexible and Highly Sensitive Pressure Sensor Based on Microdome-Patterned PDMS Forming with Assistance of Colloid Self-Assembly and Replica Technique for Wearable Electronics

Zhang, Yuan, Hu, Yougen, Zhu, Pengli, Han, Fei, Zhu, Yu, Sun, Rong, Wong, Ching-Ping·2017·ACS Applied Materials & Interfaces

Abstract

Abstract Flexible pressure sensors are one of the vital component units in the next generation of wearable electronics for monitoring human physiological signals. In order to improve the sensing properties of the sensors, we demonstrate flexible, tunably resistive pressure sensors based on elastic microstructured polydimethylsiloxane (PDMS) film via a simple, low-cost colloid self-assembly technology, which uses monodispersed polystyrene (PS) microspheres as monolayer and an ordered sacrificial template. The sensors exhibit high sensitivity of −15 kPa–1 under low pressure (<100 Pa), with fast response time (<100 ms), high stability over 1000 cycles of pressure loading/unloading, low-pressure detection limit of 4 Pa, and wide working pressure regime (<5 kPa) by optimizing the size of PS microspheres. Moreover, the multipixel arrays of the pressure sensor are fabricated to illustrate the sensing ability of space pressure distribution. The developed flexible pressure sensors are successfully used to detect human neck pulse, show great promise for monitoring human body motions, and have potential applications in wearable devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.7b09617

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 252

Metadata

Authors
Zhang, Y., Hu, Y., Zhu, P., Han, F., Zhu, Y., Sun, R., & Wong, C.-P.
Venue
ACS Applied Materials & Interfaces
Published
2017-10-06
Volume
9
Issue
41
Pages
35968-35976
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2760706646
Cited by
252
References
10
FWCI
9.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.