CoChat

Laser Direct Writing of a High-Performance All-Graphene Humidity Sensor Working in a Novel Sensing Mode for Portable Electronics

Cai, Jinguang, Lv, Chao, Aoyagi, Eiji, Ogawa, Sayaka, Watanabe, Akira · 2018 · ACS Applied Materials & Interfaces
Cited by 110

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

This paper reports a fast and highly sensitive all-graphene humidity sensor working in a novel alternating current (ac) detection mode for the first time, which is capable of sensing humidity on a smartphone for portable electronics. The humidity sensor is based on an interdigitated reduced graphene oxide/graphene oxide/rGO (rGO/GO/rGO) structure patterned by a facile laser direct writing method. It works in an ac sensing mode with a rectangular input voltage wave and measures the output voltage wave instead of conventional resistance, impedance, or capacitance, exhibiting a dramatically enhanced sensitivity by about 45 times compared to the low and unstable response in dc mode. The humidity sensor shows an obvious response to the relative humidity (RH) ranging from RH 6.3% to RH 100%. The response and recovery toward humidity change are almost instantaneous, and the corresponding costed times including humidity rise and decay times are less than 1.9 and 3.9 s, respectively, which are among the best results in the literature. The sensor also exhibits outstanding cycling stability, flexibility, and long-term stability (>1 year), as well as good reproducibility of device preparation. Besides, it can be easily connected to an iPhone and the humidity sensing can be conducted with an oscilloscope application on iOS. What's more, an electronic circuit simulation method was employed to fit the output waves, which can not only explain the sensing mechanism, but also determine the resistance and capacitance of the rGO/GO/rGO structure, agreeing well with the results obtained from the electrochemical measurements. It can be reasonably expected that the approach combining humidity sensing and electronic circuit simulation can be applied in real-time monitoring on a smartphone based on the Internet of things and big data technologies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.8b07373

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 110

Metadata

Authors
Cai, J., Lv, C., Aoyagi, E., Ogawa, S., & Watanabe, A.
Venue
ACS Applied Materials & Interfaces
Published
2018-06-22
Volume
10
Issue
28
Pages
23987-23996
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2809589226
Cited by
110
References
4
FWCI
4.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laser Direct Writing of a High-Performance All-Graphene Humidity Sensor Working in a Novel Sensing Mode for Portable Electronics. https://app.cochat.ai/papers/10.1021/acsami.8b07373
The paper
Cai, J., Lv, C., Aoyagi, E., Ogawa, S., & Watanabe, A. (2018). Laser Direct Writing of a High-Performance All-Graphene Humidity Sensor Working in a Novel Sensing Mode for Portable Electronics. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.8b07373

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.