The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Flexible Room-Temperature NH3 Sensor for Ultrasensitive, Selective, and Humidity-Independent Gas Detection
Abstract
Ammonia (NH 3 ) is an irritant gas with a unique pungent odor; sub-parts per million-level breath ammonia is a medical biomarker for kidney disorders and Helicobacter pylori bacteria-induced stomach infections. The humidity varies in both ambient environment and exhaled breath, and thus humidity dependence of gas-sensing characteristics is a great obstacle for real-time applications. Herein, flexible, humidity-independent, and room-temperature ammonia sensors are fabricated by the thermal evaporation of CuBr on a polyimide substrate and subsequent coating of a nanoscale moisture-blocking CeO 2 overlayer by electron-beam evaporation. CuBr sensors coated with a 100 nm-thick CeO 2 overlayer exhibits an ultrahigh response (resistance ratio) of 68 toward 5 ppm ammonia with excellent gas selectivity, rapid response, reversibility, and humidity-independent sensing characteristics at room temperature. In addition, the sensing performance remains stable after repetitive bending and long-term operation. Moreover, the sensors exhibit significant response to the simulated exhaled breath of patients with H. pylori infection; the simulated breath contains 50 ppb NH 3 . The sensors thus show promising potential in detecting sub-parts per million-level NH 3, regardless of humidity fluctuations, which can open up new applications in wearable devices for in situ medical diagnosis and indoor/outdoor environment monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Choi, S.-J., Kim, S.-J., & Kim, I.-D. (2016) · NPG Asia Materials · doi:10.1038/am.2016.150 · Cited by 128
Cited by
Li, Z., Li, H., Wu, Z., Wang, M., Luo, J., Torun, H., Hu, P., Yang, C., Grundmann, M., Liu, X., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01365a · Cited by 760
Self-citationEvolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Breath VOC analysis and machine learning approaches for disease screening: a review
P, H., Rangarajan, M., & Pandya, H. J. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/acb283 · Cited by 37
Metadata
- Authors
- Li, H.-Y., Lee, C.-S., Kim, D. H., & Lee, J.-H.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-07-27
- Volume
- 10
- Issue
- 33
- Pages
- 27858-27867
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2883061794
- Cited by
- 310
- References
- 2
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Room-Temperature NH3 Sensor for Ultrasensitive, Selective, and Humidity-Independent Gas Detection. https://app.cochat.ai/papers/10.1021/acsami.8b09169
- The paper
- Li, H.-Y., Lee, C.-S., Kim, D. H., & Lee, J.-H. (2018). Flexible Room-Temperature NH3 Sensor for Ultrasensitive, Selective, and Humidity-Independent Gas Detection. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.8b09169
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.