Potent Anti-adhesion Barrier Combined Biodegradable Hydrogel with Multifunctional Turkish Galls Extract
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Clinically, postoperative adhesions are common and serious complications, which almost always happen after abdominal or pelvic surgery. The adhesion development process is accompanied by increased inflammatory cell infiltration and oxygen-free radical production. In this study, the naturally occurring antioxidative and anti-inflammatory compounds extracted from Turkish galls by ethyl acetate (GEA) were encapsulated into an injectable and biodegradable thermosensitive hydrogel. Antiadhesion efficacy of the barrier system (GEA-NP/H) was tested on a rat peritoneum injury-cecum abrasion model. Upon injection, the mildly viscous liquid formed a potent physical barrier over the injured cecum and peritoneum without any additional cross-linkers or light sources. Once formed, GEA-NP/H acted as a durable wound dressing for more than 5 days, as well as a sustained drug depot of GEA. The polymer hydrogel can be degraded and absorbed gradually. After 14 days, severe adhesion occurred among rats treated with normal saline and GEA-loaded nanoparticles (GEA-NP). Whereas, frequency of score 1 adhesion among the blank hydrogel group is 30%, and 90% of the rats from GEA-NP/H group exhibited no adhesion. In addition, pathological sections and scanning electron microscopy assay demonstrated that operative defects treated with GEA-NP/H suffered from mild oxidative stress and inflammatory damages at early days after injury, as well as accelerated wound healing and more mature mesothelial cell deposition at the 14th day in contrast to the blank hydrogel treatment. Therefore, the study provided an available biodegradable hydrogel barrier to effectively prevent postsurgical adhesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An overview of injectable polymeric hydrogels for tissue engineering
Sivashanmugam, A., Arun Kumar, R., Vishnu Priya, M., Nair, S. V., & Jayakumar, R. (2015) · European Polymer Journal · doi:10.1016/j.eurpolymj.2015.05.014 · Cited by 366
Shen, W., Chen, X., Luan, J., Wang, D., Yu, L., & Ding, J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b11998 · Cited by 138
Cited by
Biomaterials to Prevent Post-Operative Adhesion
Park, H., Baek, S., Kang, H., & Lee, D. (2020) · Materials · doi:10.3390/ma13143056 · Cited by 96
An, J. M., Shahriar, S. M. S., Hasan, M. N., Cho, S., & Lee, Y.-K. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c21938 · Cited by 40
Akhlaghi, S., Ebrahimnia, M., Niaki, D. S., Solhi, M., Rabbani, S., & Haeri, A. (2023) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2023.104539 · Cited by 25
Metadata
- Authors
- Li, X., Zou, B., Zhao, N., Wang, C., Du, Y., Mei, L., Wang, Y., Ma, S., Tian, X., He, J., Tong, A., Zhou, L., Han, B., & Guo, G.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-07-05
- Volume
- 10
- Issue
- 29
- Pages
- 24469-24479
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2825673589
- Cited by
- 47
- References
- 2
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.