The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improved Piezoelectric Sensing Performance of P(VDF–TrFE) Nanofibers by Utilizing BTO Nanoparticles and Penetrated Electrodes
Abstract
Piezoelectric polymers with good flexibility have attracted tremendous attention in wearable sensors and energy harvesters. As the piezoelectricity of polymers such as polyvinylidene fluoride (PVDF) and polyvinylidene fluoride–trifluoroethylene [P(VDF–TrFE)] is lower than that of their ceramic counterparts, various approaches have been employed to improve the piezoelectric output of PVDF-based sensors, such as electrospinning, heat annealing, nanoconfinement, polymer blending, and nanoparticle addition. Here, we report two strategies to improve the piezoelectric sensing performance of polymer-based piezoelectric nanofibers, which include the formation of barium titanate (BTO)/P(VDF–TrFE) composite nanofibers and fabrication of penetrated electrodes to enlarge the interfacial area. BTO/P(VDF–TrFE) nanofibers with a BTO weight fraction of 5 wt % exhibit the maximum β-phase crystallinity and piezoelectricity. The piezoelectric output of the BTO/P(VDF–TrFE) nanofiber mat is significantly improved compared with that of pristine P(VDF–TrFE), which is confirmed by piezoresponse force microscopy (PFM) and compression loading tests. In order to form the penetrated electrodes, oxygen (O 2 ) plasma treatment is employed, followed by an electroless plating process. The BTO/P(VDF–TrFE) nanofibers with penetrated electrodes demonstrate increased dielectric constants and enhanced piezoelectric outputs. A BTO/P(VDF–TrFE) nanofiber-based sensor with penetrated electrodes is capable of discerning the energy of a free-falling ball as low as 0.6 μJ and sensing the movement of a walking ant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, J. S., Shin, K.-Y., Cheong, O. J., Kim, J. H., & Jang, J. (2015) · Scientific Reports · doi:10.1038/srep07887 · Cited by 199
Cited by
Boosting piezoelectric response of PVDF-TrFE via MXene for self-powered linear pressure sensor
Wang, S., Shao, H.-Q., Liu, Y., Tang, C.-Y., Zhao, X., Ke, K., Bao, R.-Y., Yang, M.-B., & Yang, W. (2021) · Composites Science and Technology · doi:10.1016/j.compscitech.2020.108600 · Cited by 359
Sharma, A., Ansari, M. Z., & Cho, C. (2022) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2022.113934 · Cited by 95
Yang, C.-R., Lin, M.-F., Huang, C.-K., Huang, W.-C., Tseng, S.-F., & Chiang, H.-H. (2022) · Measurement · doi:10.1016/j.measurement.2022.111817 · Cited by 77
Self-Powered Multifunctional Electronic Skin for a Smart Anti-Counterfeiting Signature System
Guo, H., Wan, J., Wu, H., Wang, H., Miao, L., Song, Y., Chen, H., Han, M., & Zhang, H. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c03510 · Cited by 70
Kim, D., Yang, Z., Cho, J., Park, D., Kim, D. H., Lee, J., Ryu, S., Kim, S., & Kim, M. (2023) · EcoMat · doi:10.1002/eom2.12384 · Cited by 64
Metadata
- Authors
- Hu, X., Yan, X., Gong, L., Wang, F., Xu, Y., Feng, L., Zhang, D., & Jiang, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-01-24
- Volume
- 11
- Issue
- 7
- Pages
- 7379-7386
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2914040069
- Cited by
- 169
- References
- 1
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.