Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 217

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Locally Concentrated LiPF6 in a Carbonate-Based Electrolyte with Fluoroethylene Carbonate as a Diluent for Anode-Free Lithium Metal Batteries

Hagos, Tesfaye Teka, Thirumalraj, Balamurugan, Huang, Chen-Jui, Abrha, Ljalem Hadush, Hagos, Teklay Mezgebe, Berhe, Gebregziabher Brhane, Bezabh, Hailemariam Kassa, Cherng, Jim, Chiu, Shuo-Feng, Su, Wei-Nien, Hwang, Bing-Joe·2019·ACS Applied Materials & Interfaces

Abstract

Currently, concentrated electrolyte solutions are attracting special attention because of their unique characteristics such as unusually improved oxidative stability on both the cathode and anode sides, the absence of free solvent, the presence of more anion content, and the improved availability of Li + ions. Most of the concentrated electrolytes reported are lithium bis(fluorosulfonyl)imide (LiFSI) salt with ether-based solvents because of the high solubility of salts in ether-based solvents. However, their poor anti-oxidation capability hindered their application especially with high potential cathode materials (>4.0 V). In addition, the salt is very costly, so it is not feasible from the cost analysis point of view. Therefore, here we report a locally concentrated electrolyte, 2 M LiPF 6, in ethylene carbonate/diethyl carbonate (1:1 v/v ratio) diluted with fluoroethylene carbonate (FEC), which is stable within a wide potential range (2.5–4.5 V). It shows significant improvement in cycling stability of lithium with an average Coulombic efficiency (ACE) of ∼98% and small voltage hysteresis (∼30 mV) with a current density of 0.2 mA/cm 2 for over 1066 h in Li||Cu cells. Furthermore, we ascertained the compatibility of the electrolyte for anode-free Li–metal batteries (AFLMBs) using Cu||LiNi 1/3 Mn 1/3 Co 1/3 O 2 (NMC, ∼2 mA h/cm 2 ) with a current density of 0.2 mA/cm 2 . It shows stable cyclic performance with ACE of 97.8 and 40% retention capacity at the 50th cycle, which is the best result reported for carbonate-based solvents with AFLMBs. However, the commercial carbonate-based electrolyte has <90% ACE and even cannot proceed more than 15 cycles with retention capacity >40%. The enhanced cycle life and well retained in capacity of the locally concentrated electrolyte is mainly because of the synergetic effect of FEC as the diluent to increase the ionic conductivity and form stable anion-derived solid electrolyte interphase. The locally concentrated electrolyte also shows high robustness to the effect of upper limit cutoff voltage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.8b21052

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Hagos, T. T., Thirumalraj, B., Huang, C.-J., Abrha, L. H., Hagos, T. M., Berhe, G. B., Bezabh, H. K., Cherng, J., Chiu, S.-F., Su, W.-N., & Hwang, B.-J.
Venue
ACS Applied Materials & Interfaces
Published
2019-02-21
Volume
11
Issue
10
Pages
9955-9963
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2916058073
Cited by
217
References
2
FWCI
9.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.