CoChat

Elucidating the Dynamic Nature of Fuel Cell Electrodes as a Function of Conditioning: An ex Situ Material Characterization and in Situ Electrochemical Diagnostic Study

Open access
Kabir, Sadia, Myers, Deborah J., Kariuki, Nancy, Park, Jaehyung, Wang, Guanxiong, Baker, Andrew, Macauley, Natalia, Mukundan, Rangachary, More, Karren L., Neyerlin, K. C. · 2019 · ACS Applied Materials & Interfaces
Cited by 153

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

To increase the commercialization of fuel cell electric vehicles, it is imperative to improve the activity and performance of electrocatalysts through combined efforts focused on material characterization and device-level integration. Obtaining fundamental insights into the ongoing structural and compositional changes of electrocatalysts is crucial for not only transitioning an electrode from its as-prepared to functional state, also known as "conditioning", but also for establishing intrinsic electrochemical performances. Here, we investigated several oxygen reduction reaction (ORR) electrocatalysts via in situ and ex situ characterization techniques to provide fundamental insights into the interfacial phenomena that enable peak ORR mass activity and high current density performance. A mechanistic understanding of a fuel cell conditioning procedure is described, which encompasses voltage cycling and subsequent voltage recovery (VR) steps at low potential. In particular, ex situ membrane electrode assembly characterization using transmission electron microscopy and ultra-small angle X-ray scattering were performed to determine changes in carbon and Pt particle size and morphology, while in situ electrochemical diagnostics were performed either during or after specific points in the testing protocol to determine the electrochemical and interfacial changes occurring on the catalyst surface responsible for oxygen transport resistances through ionomer films. The results demonstrate that the voltage cycling (break-in) step aids in the removal of sulfate and fluoride and concomitantly reduces non-Fickian oxygen transport resistances, especially for catalysts where Pt is located within the pores of the carbon support. Subsequent low voltage holds at low temperature and oversaturated conditions, i.e., VR cycles, serve to improve mass activities by a factor of two to three, through a combined removal of contaminants, surface-blocking species (e.g., oxides), and rearrangement of the catalyst atomic structure (e.g., Pt-Pt and Pt-Co coordination).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.9b11365

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 153

Metadata

Authors
Kabir, S., Myers, D. J., Kariuki, N., Park, J., Wang, G., Baker, A., Macauley, N., Mukundan, R., More, K. L., & Neyerlin, K. C.
Venue
ACS Applied Materials & Interfaces
Published
2019-11-06
Volume
11
Issue
48
Pages
45016-45030
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2983297728
Cited by
153
References
14
FWCI
3.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.