The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Hierarchically Rough Structured and Self-Powered Pressure Sensor Textile for Motion Sensing and Pulse Monitoring
Abstract
Nowadays, real-time human motion sensing and pulse monitoring can provide significant basis for health assessment and medical diagnosis. Nevertheless, it is still a big challenge to design a lightweight, flexible, and energy-sustainable pressure sensor with high sensitivity and breathability. Here, we fabricated a triboelectric all-fiber structured pressure sensor via a facile electrospinning technique. The constructed sensor textile holds a composite structure made up of a polyvinylidene fluoride/Ag nanowire nanofibrous membrane (NFM), an ethyl cellulose NFM, and two layers of conductive fabrics. This wearable device with high shape adaptability exhibited excellent sensing capability because of the introduced hierarchically rough structure on the nanofibers. The sensitivity can reach up to 1.67 and 0.20 V·kPa –1 in the pressure range of 0–3 and 3–32 kPa, respectively. The fabricated sensor textile also showed a superior mechanical stability even after continuous operation of 7200 working cycles. This sensor textile was easily conformable on different desired body parts for dynamic motion sensing and real-time pulse monitoring. It can work in a self-powered manner to detect and quantify various human motions associated with joints, such as elbows, knees, and ankles. Additionally, it can be placed on the carotid artery to capture the pulse signals, serving as a reliable way to reflect the state of health. This work has great possibilities to promote the rapid advancement and broad applications of multifunctional pressure sensors and next-generation wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Sustainably powering wearable electronics solely by biomechanical energy
Wang, J., Li, S., Yi, F., Zi, Y., Lin, J., Wang, X., Xu, Y., & Wang, Z. L. (2016) · Nature Communications · doi:10.1038/ncomms12744 · Cited by 648
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301
Cited by
Luo, J., Gao, S., Luo, H., Wang, L., Huang, X., Guo, Z., Lai, X., Lin, L., Li, R. K. Y., & Gao, J. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126898 · Cited by 483
Electrospun nanofiber based TENGs for wearable electronics and self-powered sensing
Babu, A., Aazem, I., Walden, R., Bairagi, S., Mulvihill, D. M., & Pillai, S. C. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.139060 · Cited by 293
Electrospun nanofiber-based soft electronics
Wang, Y., Yokota, T., & Someya, T. (2021) · NPG Asia Materials · doi:10.1038/s41427-020-00267-8 · Cited by 267
Metadata
- Authors
- Lou, M., Abdalla, I., Zhu, M., Yu, J., Li, Z., & Ding, B.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-12-16
- Volume
- 12
- Issue
- 1
- Pages
- 1597-1605
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2995101173
- Cited by
- 169
- References
- 3
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.