Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

A Self-Powered Wearable Pressure Sensor and Pyroelectric Breathing Sensor Based on GO Interfaced PVDF Nanofibers

Roy, Krittish, Ghosh, Sujoy Kumar, Sultana, Ayesha, Garain, Samiran, Xie, Mengying, Bowen, Christopher Rhys, Henkel, Karsten, Schmeiβer, Dieter, Mandal, Dipankar·2019·ACS Applied Nano Materials

Abstract

This paper reports a self-powered, flexible, piezo- and pyro-electric hybrid nanogenerator (NG) device that can be fixed on different locations of human skin for detecting static and dynamic pressure variations and can also monitor temperature fluctuations during the respiration process. An efficient and cost-effective fabrication strategy has been developed to create electrospun poly(vinylidene fluoride) (PVDF)/graphene oxide (GO) nanofibers, which are used to create a highly sensitive wearable pressure sensor and pyroelectric breathing sensor. The sensor can accurately and rapidly detect pressures as low as 10 Pa with a high sensitivity (4.3 V/kPa), a key performance indicator for wearable sensors. Importantly, the sensor exhibits a high sensitivity to bending and stretching by finger, wrist, and elbow. The pressure sensor is also highly sensitive to vocal vibrations when attached to the human throat. The device can generate a maximum output power density of ∼6.2 mW/m 2 when subjected to a compressive stress, which enhances its range of applications. Moreover, it is demonstrated that doping with GO improves the pyroelectric energy harvesting and sensing performance of the device under repeated temperature fluctuations. The PVDF/GO-based nanogenerator has a maximum pyroelectric output power density of ∼1.2 nW/m 2 and can sense temperature changes during respiration, which makes it promising as a pyroelectric breathing sensor. It is demonstrated that processing of the PVDF-GO self-powered multifunctional pressure and pyroelectric breathing sensor can be up-scaled for fabricating compact and high-performance electronic skins for application in health monitoring, motion detection, and portable electronics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsanm.9b00033

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 274

Metadata

Authors
Roy, K., Ghosh, S. K., Sultana, A., Garain, S., Xie, M., Bowen, C. R., Henkel, K., Schmeiβer, D., & Mandal, D.
Venue
ACS Applied Nano Materials
Published
2019-03-07
Volume
2
Issue
4
Pages
2013-2025
ISSN
2574-0970 (ISSN-L)
OpenAlex
W2922101591
Cited by
274
References
5
FWCI
10.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Self-Powered Wearable Pressure Sensor and Pyroelectric Breathing Sensor Based on GO Interfaced PVDF Nanofibers. https://app.cochat.ai/papers/10.1021/acsanm.9b00033
The paper
Roy, K., Ghosh, S. K., Sultana, A., Garain, S., Xie, M., Bowen, C. R., Henkel, K., Schmeiβer, D., & Mandal, D. (2019). A Self-Powered Wearable Pressure Sensor and Pyroelectric Breathing Sensor Based on GO Interfaced PVDF Nanofibers. ACS Applied Nano Materials. https://doi.org/10.1021/acsanm.9b00033

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.