Blood Oxygenation Using Fluoropolymer-Based Artificial Lung Membranes

Park, Ahrumi, Song, Yejin, Yi, Eunsung, Duy Nguyen, Bao Tran, Han, Dongje, Sohn, EunHo, Park, YouIn, Jung, JunTae +3 more·2020·ACS Biomaterials Science & Engineering

Abstract

Artificial lung (AL) membranes are used for blood oxygenation for patients undergoing open-heart surgery or acute lung failures. Current AL technology employs polypropylene and polymethylpentene membranes. Although effective, these membranes suffer from low biocompatibility, leading to undesired blood coagulation and hemolysis over a long term. In this work, we propose a new generation of AL membranes based on amphiphobic fluoropolymers. We employed poly(vinylidene- co -hexafluoropropylene), or PVDF- co -HFP, to fabricate macrovoid-free membranes with an optimal pore size range of 30–50 nm. The phase inversion behavior of PVDF- co -HFP was investigated in detail for structural optimization. To improve the wetting stability of the membranes, the fabricated membranes were coated using Hyflon AD60X, a type of fluoropolymer with an extremely low surface energy. Hyflon-coated materials displayed very low protein adsorption and a high contact angle for both water and blood. In the hydrophobic spectrum, the data showed an inverse relationship between the surface free energy and protein adsorption, suggesting an appropriate direction with respect to biocompatibility for AL research. The blood oxygenation performance was assessed using animal sheep blood, and the fabricated fluoropolymer membranes showed competitive performance to that of commercial polyolefin membranes without any detectable hemolysis. The data also confirmed that the bottleneck in the blood oxygenation performance was not the membrane permeance but rather the rate of mass transfer in the blood phase, highlighting the importance of efficient module design.

Integrity signals

Registry

Crossref · 10.1021/acsbiomaterials.0c01251

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In medical devices, fluoropolymer-based structures offer a superior and safer alternative to devices made from other types of polymers; polypropylene and polymethylpentene artificial lung membranes often exhibit inadequate biocompatibility, causing unwanted blood clotting and long-term hemolysis, whereas a novel fluoropolymer-based membrane has demonstrated optimal performance with no detectable

    “For example, in the field of medical devices, fluoropolymer-based structures offer a superior and safer alternative to devices made from other types of polymers; when polypropylene and polymethylpentene are used to make artificial lung membranes for blood oxygenation during open-heart surgery or acute lung failure, they often exhibit inadequate biocompatibility, resulting in unwanted blood”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Park, A., Song, Y., Yi, E., Duy Nguyen, B. T., Han, D., Sohn, E., Park, Y., Jung, J., Lee, Y. M., Cho, Y. H., & Kim, J. F.
Affiliations
  • Korea Research Institute of Chemical Technology (KR)
  • Department of Energy and Chemical Engineering, Incheon National University, Incheon 22012, Republic of Korea
  • Interface Material and Chemical Engineering Research Center, Korea Research Institute of Chemical Technology (KRICT), Daejeon 305-600, Republic of Korea
  • Membrane Research Center, Korea Research Institute of Chemical Technology (KRICT), Daejeon 305-600, Republic of Korea
  • Hanyang University (KR)
  • Incheon National University (KR)
Corresponding author
  • Cho, Young Hoon
  • Kim, Jeong F.
Venue
ACS Biomaterials Science & Engineering
Published
2020-10-26
Volume
6
Issue
11
Pages
6424-6434
ISSN
2373-9878 (ISSN-L)
OpenAlex
W3095168245
Cited by
54
References
50
Citations by year
2026: 4 · 2025: 7 · 2024: 14 · 2023: 16 · 2022: 7 · 2021: 6
FWCI
2.22
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Biomaterials Science & Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Korea Research Institute of Chemical Technology (BSF20-254)
  • National Research Foundation of Korea (2019M3E6A106479912, 2019R1G1A109477811, 2020R1C1C100787611)
  • Korea Toray Science Foundation (2019)
Topics
  • Physical Sciences › Environmental Science › Water Science and Technology › Membrane Separation Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Membrane Separation and Gas Transport
  • Physical Sciences › Engineering › Biomedical Engineering › Mechanical Circulatory Support Devices
Keywords
blood oxygenation, fluorinated polymers, poly(vinylidene fluoride-co-hexafluoropropylene), phase inversion, protein adsorption, biocompatibility, hemolysis, coagulation, surface energy, mass transfer, membrane permeance, open heart surgery, acute lung failure
MeSH terms
Adsorption, Animals, Humans, Lung, Membranes, Membranes, Artificial, Polyvinyls, Sheep

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review