The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Low Cytotoxicity and Genotoxicity of Two-Dimensional MoS2 and WS2
Abstract
Atomically thin transition-metal dichalcogenides (TMDs) have attracted considerable interest because of their unique combination of properties, including photoluminescence, high lubricity, flexibility, and catalytic activity. These unique properties suggest future uses for TMDs in medical applications such as orthodontics, endoscopy, and optogenetics. However, few studies thus far have investigated the biocompatibility of mechanically exfoliated and chemical vapor deposition (CVD)-grown pristine two-dimensional TMDs. Here, we evaluate pristine molybdenum disulfide (MoS 2 ) and tungsten disulfide (WS 2 ) in a series of biocompatibility tests, including live–dead cell assays, reactive oxygen species (ROS) generation assays, and direct assessment of cellular morphology of TMD-exposed human epithelial kidney cells (HEK293f). Genotoxicity and genetic mutagenesis were also evaluated for these materials via the Ames Fluctuation test with the bacterial strain S. typhimurium TA100. Scanning electron microscopy of cultured HEK293f cells in direct contact with MoS 2 and WS 2 showed no impact on cell morphology. HEK293f cell viability, evaluated by both live–dead fluorescence labeling to detect acute toxicity and ROS to monitor for apoptosis, was unaffected by these materials. Exposure of bacterial cells to these TMDs failed to generate genetic mutation. Together, these findings demonstrate that neither mechanically exfoliated nor CVD-grown TMDs are deleterious to cellular viability or induce genetic defects. Thus, these TMDs appear biocompatible for future application in medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Characteristics of a human cell line transformed by DNA from human adenovirus type 5
Graham, F. L., Russell, W. C., Smiley, J., & Nairn, R. (1977) · Journal of General Virology · doi:10.1099/0022-1317-36-1-59 · Cited by 4,793
Reactive oxygen species, cellular redox systems, and apoptosis
Circu, M. L., & Aw, T. Y. (2010) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2009.12.022 · Cited by 3,340
Cited by
Two-dimensional materials in biomedical, biosensing and sensing applications
Rohaizad, N., Mayorga-Martinez, C. C., Fojtů, M., Latiff, N. M., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00150c · Cited by 506
Light‐Responsive Inorganic Biomaterials for Biomedical Applications
Lee, H. P., & Gaharwar, A. K. (2020) · Advanced Science · doi:10.1002/advs.202000863 · Cited by 337
Metadata
- Authors
- Appel, J. H., Li, D. O., Podlevsky, J. D., Debnath, A., Green, A. A., Wang, Q. H., & Chae, J.
- Venue
- ACS Biomaterials Science & Engineering
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-03-03
- Volume
- 2
- Issue
- 3
- Pages
- 361-367
- ISSN
- 2373-9878 (ISSN-L)
- OpenAlex
- W2295119095
- Cited by
- 229
- References
- 3
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low Cytotoxicity and Genotoxicity of Two-Dimensional MoS2 and WS2. https://app.cochat.ai/papers/10.1021/acsbiomaterials.5b00467
- The paper
- Appel, J. H., Li, D. O., Podlevsky, J. D., Debnath, A., Green, A. A., Wang, Q. H., & Chae, J. (2016). Low Cytotoxicity and Genotoxicity of Two-Dimensional MoS2 and WS2. ACS Biomaterials Science & Engineering. https://doi.org/10.1021/acsbiomaterials.5b00467
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.