CoChat

Nonglutaraldehyde Fixation for off the Shelf Decellularized Bovine Pericardium in Anticalcification Cardiac Valve Applications

Liu, Jing, Jing, Huimin, Qin, Yibo, Li, Binhan, Sun, Zhiting, Kong, Deling, Leng, Xigang, Wang, Zhihong · 2019 · ACS Biomaterials Science & Engineering
Cited by 47

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

In valvular replacement surgery, especially in the construction of bioprosthetic valves with decellularized pericardial xenograft, glutaraldehyde (GA) is routinely utilized as the golden standard reagent to fix bovine or porcine pericardial tissues. However, the apparent defects of GA, including cytotoxicity and calcification, increase the probability of leaflet failure and motivate the exploration for alternatives. Thus, the aim of this study is to develop nonglutaraldehyde combined-cross-linking reagents composed of alginate-EDC/NHS (Alg) or oxidized alginate-EDC/NHS (Alg-CHO) as substitute for GA, which is confirmed to be less toxic and more biocompatible. Evaluations of the fixed acellular bovine pericardial tissues included mechanical performance, thermodynamics/enzymatic/in vivo stability tests, blood compatibility assay, cytocompatibility assay, in vitro anticalcification, and in vivo anticalcification assay by subcutaneous implantation in juvenile Wistar rats. The data revealed that the tissues fixed with the combined cross-linking reagents were superior to GA control and commercially available Sino product in terms of better in vitro hemocompatibility and cytocompatibility, lower calcification levels, better thermodynamics stability, and better regenerative capacity in subcutaneous implants, while the mechanical strength and in vivo stability were comparable. Considering all above performances, it indicated that both Alg and Alg-CHO are appropriate to replace GA as the cross-linkers for biological tissue, particularly as a nonglutaraldehyde fixation for off the shelf decellularized bovine pericardial tissue in the anticalcification cardiac valve applications. Nevertheless, studies on the long-term durability and calcification-resistance capacity in large animal model are further needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsbiomaterials.8b01311

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Liu, J., Jing, H., Qin, Y., Li, B., Sun, Z., Kong, D., Leng, X., & Wang, Z.
Venue
ACS Biomaterials Science & Engineering
Published
2019-01-30
Volume
5
Issue
3
Pages
1452-1461
ISSN
2373-9878 (ISSN-L)
OpenAlex
W2913257775
Cited by
47
References
5
FWCI
5.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.