Abstract
The long-term durability of the catalyst layers of a low-working temperature fuel cell such as a polymer electrolyte membrane fuel cell (PEMFC) is of significant scientific interest because of their operation criteria and high initial cost. Identification of degradation mechanisms quantitatively during an accelerated stress test (AST) is essential for assessing and improving the durability of such catalyst layers. In this study, we present a quantitative analysis of the degradation mechanisms such as (i) electronic connectivity loss due to carbon support corrosion, (ii) proton connectivity loss due to ionomer/catalyst interface loss, (iii) catalyst loss due to dissolution or detachment, and (iv) physical surface area loss due to particle growth that is responsible for the electrochemical surface area (ECSA) loss in Pt-based catalyst layers for PEMFCs during an AST performed through potential cycling (linear sweep cyclic voltammetry) between 0.4 and 1.6 V for 7000 cycles in Ar-saturated 1 M H 2 SO 4 . Using a half-membrane electrode assembly (half-MEA), where a gas diffusion electrode with genuine three-phase boundaries is used as a working electrode through a solid electrolyte, we have observed the ECSA loss due to ionomer/catalyst interface loss and identified a catalyst heterogeneous degradation pattern during an AST. Results suggest a significant ECSA loss due to catalyst isolation (∼64% of ECSA loss) from loss of electron and proton connectivities by catalyst support corrosion (∼45%) and ionomer/catalyst interface loss (∼19%), followed by particle growth (∼30%) and dissolution/detachment (6%). Such knowledge and methodology can effectively contribute to catalyst material screening and electrode structure development to advance the PEMFC technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Advances in Electrocatalysts for Oxygen Reduction Reaction
Shao, M., Chang, Q., Dodelet, J.-P., & Chenitz, R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00462 · Cited by 3,903
A review of PEM fuel cell durability: Degradation mechanisms and mitigation strategies
Wu, J., Yuan, X. Z., Martin, J. J., Wang, H., Zhang, J., Shen, J., Wu, S., & Merida, W. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.06.006 · Cited by 1,587
Understanding and approaches for the durability issues of Pt-based catalysts for PEM fuel cell
Shao, Y., Yin, G., & Gao, Y. (2007) · Journal of Power Sources · doi:10.1016/j.jpowsour.2007.07.004 · Cited by 1,197
Stamenkovic, V. R., Mun, B. S., Mayrhofer, K. J. J., Ross, P. N., & Markovic, N. M. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0600476 · Cited by 974
Takasaki, F., Matsuie, S., Takabatake, Y., Noda, Z., Hayashi, A., Shiratori, Y., Ito, K., & Sasaki, K. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3625918 · Cited by 144
Cited by
He, Y., Liu, S., Priest, C., Shi, Q., & Wu, G. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00903e · Cited by 771
Zhao, J., & Li, X. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.112022 · Cited by 430
Surface engineering for stable electrocatalysis
Do, V.-H., & Lee, J.-M. (2024) · Chemical Society Reviews · doi:10.1039/d3cs00292f · Cited by 167
Sharma, R., & Andersen, S. M. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b14622 · Cited by 73
Self-citationSharma, R., Wang, Y., Li, F., Chamier, J., & Andersen, S. M. (2019) · ACS Omega · doi:10.1021/acsomega.9b02351 · Cited by 49
Self-citation
Metadata
- Authors
- Sharma, R., & Andersen, S. M.
- Venue
- ACS Catalysis
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-03-14
- Volume
- 8
- Issue
- 4
- Pages
- 3424-3434
- ISSN
- 2155-5435 (ISSN-L)
- OpenAlex
- W2792829842
- Cited by
- 103
- References
- 5
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.