Analysis of Current DNA Encoded Library Screening Data Indicates Higher False Negative Rates for Numerically Larger Libraries
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
To optimize future DNA-encoded library design, we have attempted to quantify the library size at which the signal becomes undetectable. To accomplish this we (i) have calculated that percent yields of individual library members following a screen range from 0.002 to 1%, (ii) extrapolated that ∼1 million copies per library member are required at the outset of a screen, and (iii) from this extrapolation predict that false negative rates will begin to outweigh the benefit of increased diversity at library sizes >10 8 . The above analysis is based upon a large internal data set comprising multiple screens, targets, and libraries; we also augmented our internal data with all currently available literature data. In theory, high false negative rates may be overcome by employing larger amounts of library; however, we argue that using more than currently reported amounts of library (≫10 nmoles) is impractical. The above conclusions may be generally applicable to other DNA encoded library platforms, particularly those platforms that do not allow for library amplification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA-encoded chemistry: enabling the deeper sampling of chemical space
Goodnow, R. A., Dumelin, C. E., & Keefe, A. D. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.213 · Cited by 621 · cited 1×
“interfere with the activity of pharmaceutically relevant proteins (1-14).”
Background
Cited by
Neri, D., & Lerner, R. A. (2018) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-062917-012550 · Cited by 364
“In our experience, when screening libraries with conventional affinity capture methodologies, it is convenient to ensure that individual molecules are present in a selection experiment with least 105 copies each (64,65,95,96).”
DNA-Encoded Chemical Libraries: A Comprehensive Review with Succesful Stories and Future Challenges
Gironda-Martínez, A., Donckele, E. J., Samain, F., & Neri, D. (2021) · ACS Pharmacology & Translational Science · doi:10.1021/acsptsci.1c00118 · Cited by 344
DNA-Encoded Chemistry: Drug Discovery from a Few Good Reactions
Fitzgerald, P. R., & Paegel, B. M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00789 · Cited by 219
DNA-encoded chemical libraries
Satz, A. L., Brunschweiger, A., Flanagan, M. E., Gloger, A., Hansen, N. J. V., Kuai, L., Kunig, V. B. K., Lu, X., Madsen, D., Marcaurelle, L. A., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00084-5 · Cited by 176
Self-citationMachine Learning on DNA-Encoded Libraries: A New Paradigm for Hit Finding
McCloskey, K., Sigel, E. A., Kearnes, S., Xue, L., Tian, X., Moccia, D., Gikunju, D., Bazzaz, S., Chan, B., Clark, M. A., et al. (2020) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.0c00452 · Cited by 158
Advances in Ultrahigh Throughput Hit Discovery with Tandem Mass Spectrometry Encoded Libraries
Mata, J. M., van der Nol, E., & Pomplun, S. J. (2023) · Journal of the American Chemical Society · doi:10.1021/jacs.3c04899 · Cited by 27
Metadata
- Authors
- Satz, A. L., Hochstrasser, R., & Petersen, A. C.
- Venue
- ACS Combinatorial Science
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-03-17
- Volume
- 19
- Issue
- 4
- Pages
- 234-238
- ISSN
- 2156-8944 (ISSN-L)
- 2156-8952
- OpenAlex
- W2595526189
- Cited by
- 78
- References
- 1
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.