The DOI matches its Crossref record.
Intelligent Drug Delivery System Based on Mesoporous Silica Nanoparticles Coated with an Ultra-pH-Sensitive Gatekeeper and Poly(ethylene glycol)
Abstract
Mesoporous silica nanoparticles (MSNs) exhibit significant advantages for efficient drug/gene delivery but it is hard for simple MSNs to deliver the loaded drug to the target sites of disease. Considering that there are some well-known pH differences in the body, it is a useful strategy to modify the exterior surface of MSNs with stimuli-responsive gatekeepers to realize open-close transformation of their mesopores. In this work, multifunctional pH-sensitive MSNs were designed with mixed polymeric coatings, that is, poly(ethylene glycol) (PEG) as a dispersity-enhancer and poly(2-(pentamethyleneimino)ethyl methacrylate) (PPEMA) as an ultra-pH-sensitive gatekeeper. Enhanced dispersity, high drug loading capacity, long-circulation time, pH-triggered targeting, and better cellular uptake of the multifunctional MSNs make them potential candidates for pH-sensitive drug delivery such as tumor therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The polymeric coating controls the release of guest molecules from MSNs depending on time, pH, and other factors [27,31,46].”
From Targeted Nano-Drug Delivery of Colchicine against Colon Cancer Cells by Means of Mesoporous Silica Nanoparticles (2020) · cites this paper as [46]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 25
- 10.1039/c1jm10750j · DOI
- 10.1021/ja206998x · DOI
- 10.1002/smll.201201397 · DOI
- 10.1021/jp201053d · DOI
- 10.1021/cm3037197 · DOI · Paper page
- 10.1021/nn100918a · DOI
- 10.1002/ange.200501819 · DOI
- 10.1002/anie.200705211 · DOI
- 10.1016/j.biomaterials.2013.01.084 · DOI
- 10.1021/cm703363w · DOI
- 10.1021/la104973j · DOI
- 10.1021/jp103982a · DOI
- 10.1002/anie.201005061 · DOI
- 10.1021/am3005225 · DOI
- 10.1021/jp9043978 · DOI
- 10.1039/c1jm11869b · DOI
- 10.1002/anie.201300183 · DOI
- 10.1021/la4022646 · DOI
- 10.1166/jbn.2014.1846 · DOI
- 10.1039/C4RA05270F · DOI
- 10.1021/nl0479987 · DOI
- 10.1002/anie.201100884 · DOI
- 10.1016/j.micromeso.2008.08.004 · DOI
- 10.1021/jp208494w · DOI
- 10.1016/j.biomaterials.2011.11.045 · DOI
Cited by
Sorted by citations
AbouAitah, K., Hassan, H. A., Swiderska-Sroda, A., Gohar, L., Shaker, O. G., Wojnarowicz, J., Opalinska, A., Smalc-Koziorowska, J., Gierlotka, S., & Lojkowski, W. (2020) · Cancers · doi:10.3390/cancers12010144 · Cited by 105
Metadata
- Authors
- Chen, T., Wu, W., Xiao, H., Chen, Y., Chen, M., & Li, J.
- Affiliations
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory For Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, 610041, China
- Department of Materials Science and State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai, 200433, China
- Venue
- ACS Macro Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-16
- Volume
- 5
- Issue
- 1
- Pages
- 55-58
- ISSN
- 2161-1653
- Cited by
- 87
- References
- 0
- Language
- en
- Funders
- National Natural Science Foundation of China (21534008, 51322303, 51573110)
- State Key Laboratory of Polymer Materials Engineering, Sichuan University (sklpme2014-3-01)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review