Cited by 189Advanced Sensor and Energy Harvesting MaterialsConducting polymers and applicationsNon-Invasive Vital Sign Monitoring

Adhesive Biocomposite Electrodes on Sweaty Skin for Long-Term Continuous Electrophysiological Monitoring

Open access
Yang, Hui, Ji, Shaobo, Chaturvedi, Iti, Xia, Huarong, Wang, Ting, Chen, Geng, Pan, Liang, Wan, Changjin +3 more·2020·ACS Materials Letters

Abstract

Noninvasive on-skin electrodes record the electrical potential changes from human skin, which reflect body condition and are applied for healthcare, sports management, and modern lifestyle. However, current on-skin electrodes have poor conformal properties under sweaty condition in real-life because of decreased electrode-skin adhesion with sweat film at the interface. Here, we fabricated biocomposite electrodes based on silk fibroin (SF) through interfacial polymerization, which is applicable on sweaty skin. Interfacial polymerized conductive polypyrrole (PPy) and SF are structurally interlocked and endow the whole electrode with uniform stretchability. Existence of water results in similar Young’s modulus of SF to the skin and enhanced interfacial adhesion. It keeps the electrodes conformal to skin under sweaty condition and allows reliable collection of ambulatory electrophysiological signals during sports and sweating. Wearable devices with these electrodes were used to acquire continuous and stable real-time electrocardiography (ECG) signals during running for 2 h. The collected signals can provide information for sports management and are also analyzed by artificial intelligence to show their potential for intelligent human emotion monitoring. Our strategy provides opportunities to record long-term continuous electrophysiological signals in real-life conditions for various smart monitoring systems.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsmaterialslett.0c00085

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Authors
Yang, H., Ji, S., Chaturvedi, I., Xia, H., Wang, T., Chen, G., Pan, L., Wan, C., Qi, D., Ong, Y.-S., & Chen, X.
Affiliations
Nanyang Technological University (SG)
Corresponding author
  • Ong, Yew-Soon
  • Chen, Xiaodong
Venue
ACS Materials Letters
Published
2020-03-31
Volume
2
Issue
5
Pages
478-484
ISSN
2639-4979 (ISSN-L)
OpenAlex
W3015032324
Cited by
189
References
4
Citations by year
2026: 16 · 2025: 37 · 2024: 35 · 2023: 33 · 2022: 26 · 2021: 32 · 2020: 10
FWCI
7.94
Type
journal article
Language
en
Open access
Locations
  • ACS Materials Letters (publishedVersion)
  • DR-NTU (Nanyang Technological University) (submittedVersion)
  • ResearchOnline at James Cook University (James Cook University) (submittedVersion)
Funders
  • Agency for Science, Technology and Research (A18A1b0045)
  • National Research Foundation Singapore (NRF2016NRF-NRFI001-21)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
silk fibroin, polypyrrole, interfacial polymerization, stretchable conductors, wearable devices, electrocardiogram, sports monitoring, artificial intelligence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review