Abstract
Coulter counters measure the size of particles in solution by passing them through an orifice and measuring a resistive pulse, i.e., a drop in the ionic current flowing between two electrodes placed on either side of the orifice. The magnitude of the pulse gives information on the size of the particle; however, resolution is limited by variability in the path of the translocation, due to the Brownian motion of the particle. We present a simple yet powerful modified Coulter counter that uses programmable data acquisition hardware to switch the voltage after sensing the resistive pulse of a nanoparticle passing through the orifice of a nanopipet. Switching the voltage reverses the direction of the driving force on the particle and, when this detect-switch cycle is repeated, allows us to pass an individual nanoparticle through the orifice thousands of times. By measuring individual particles more than 100 times per second we rapidly determine the distribution of the resistive pulses for each particle, which allows us to accurately determine the mean pulse amplitude and deliver considerably improved size resolution over a conventional Coulter counter. We show that single polystyrene nanoparticles can be shuttled back and forth and monitored for minutes, leading to a precisely determined mean blocking current equating to sub-angstrom size resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Filipe, V., Hawe, A., & Jiskoot, W. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0073-2 · Cited by 1,885
Observation of Single-Protein and DNA Macromolecule Collisions on Ultramicroelectrodes
Dick, J. E., Renault, C., & Bard, A. J. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b04545 · Cited by 215 · cited 1×
“Nanoparticle-like structures are also found in biology, such as viruses,(7) vesicles,(8,9) and biomacromolecules.(10) Many properties of nanoparticles are highly size-dependent;(1,3,5) thus accurate determination of their size is important for”
BackgroundSelf-citationDunevall, J., Fathali, H., Najafinobar, N., Lovric, J., Wigström, J., Cans, A.-S., & Ewing, A. G. (2015) · Journal of the American Chemical Society · doi:10.1021/ja512972f · Cited by 196
Dick, J. E., Hilterbrand, A. T., Boika, A., Upton, J. W., & Bard, A. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1504294112 · Cited by 166
Self-citation
Cited by
Nanoscale Surface Structure–Activity in Electrochemistry and Electrocatalysis
Bentley, C. L., Kang, M., & Unwin, P. R. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09828 · Cited by 271
(2021) · doi:10.1039/d1cp00661d · Cited by 103
Ronspees, A. T., & Thorgaard, S. N. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.05.006 · Cited by 46
Chávez-Ramos, A. E., Saddler, J., Katt, D., Galicia, M., & Ortiz-Ledón, C. A. (2026) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.6c00290
Metadata
- Authors
- Edwards, M. A., German, S. R., Dick, J. E., Bard, A. J., & White, H. S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-11-12
- Volume
- 9
- Issue
- 12
- Pages
- 12274-12282
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2191488834
- Cited by
- 68
- References
- 4
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.