The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
pH- and Temperature-Sensitive Hydrogel Nanoparticles with Dual Photoluminescence for Bioprobes
Abstract
This study demonstrates high contrast and sensitivity by designing a dual-emissive hydrogel particle system, whose two emissions respond to pH and temperature strongly and independently. It describes the photoluminescence (PL) response of poly(N-isopropylacrylamide) (PNIPAM)-based core/shell hydrogel nanoparticles with dual emission, which is obtained by emulsion polymerization with potassium persulfate, consisting of the thermo- and pH-responsive copolymers of PNIPAM and poly(acrylic acid) (PAA). A red-emission rare-earth complex and a blue-emission quaternary ammonium tetraphenylethylene derivative (d-TPE) with similar excitation wavelengths are inserted into the core and shell of the hydrogel nanoparticles, respectively. The PL intensities of the nanoparticles exhibit a linear temperature response in the range from 10 to 80 °C with a change as large as a factor of 5. In addition, the blue emission from the shell exhibits a linear pH response between pH 6.5 and 7.6 with a resolution of 0.1 unit, while the red emission from the core is pH-independent. These stimuli-responsive PL nanoparticles have potential applications in biology and chemistry, including bio- and chemosensors, biological imaging, cancer diagnosis, and externally activated release of anticancer drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Cited by
Fluorescent Sensors Based on Aggregation-Induced Emission: Recent Advances and Perspectives
Gao, M., & Tang, B. Z. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00551 · Cited by 666
Carbon Dot Nanothermometry: Intracellular Photoluminescence Lifetime Thermal Sensing
Kalytchuk, S., Poláková, K., Wang, Y., Froning, J. P., Cepe, K., Rogach, A. L., & Zbořil, R. (2017) · ACS Nano · doi:10.1021/acsnano.6b06670 · Cited by 310
pH ‐sensitive polymers: Classification and some fine potential applications
Ofridam, F., Tarhini, M., Lebaz, N., Gagnière, É., Mangin, D., & Elaissari, A. (2021) · Polymers for Advanced Technologies · doi:10.1002/pat.5230 · Cited by 286
Multicolor Fluorescent Polymeric Hydrogels
Wei, S., Li, Z., Lu, W., Liu, H., Zhang, J., Chen, T., & Tang, B. Z. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202007506 · Cited by 281
Stimuli-Responsive Nanomaterials for Application in Antitumor Therapy and Drug Delivery
Pham, S. H., Choi, Y., & Choi, J. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12070630 · Cited by 248
Metadata
- Authors
- Zhao, Y., Shi, C., Yang, X., Shen, B., Sun, Y., Chen, Y., Xu, X., Sun, H., Yu, K., Yang, B., & Lin, Q.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-06-16
- Volume
- 10
- Issue
- 6
- Pages
- 5856-5863
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2402044580
- Cited by
- 245
- References
- 1
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: pH- and Temperature-Sensitive Hydrogel Nanoparticles with Dual Photoluminescence for Bioprobes. https://app.cochat.ai/papers/10.1021/acsnano.6b00770
- The paper
- Zhao, Y., Shi, C., Yang, X., Shen, B., Sun, Y., Chen, Y., Xu, X., Sun, H., Yu, K., Yang, B., & Lin, Q. (2016). pH- and Temperature-Sensitive Hydrogel Nanoparticles with Dual Photoluminescence for Bioprobes. ACS Nano. https://doi.org/10.1021/acsnano.6b00770
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.