The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Energy-Looping Nanoparticles: Harnessing Excited-State Absorption for Deep-Tissue Imaging
Abstract
Near infrared (NIR) microscopy enables noninvasive imaging in tissue, particularly in the NIR-II spectral range (1000-1400 nm) where attenuation due to tissue scattering and absorption is minimized. Lanthanide-doped upconverting nanocrystals are promising deep-tissue imaging probes due to their photostable emission in the visible and NIR, but these materials are not efficiently excited at NIR-II wavelengths due to the dearth of lanthanide ground-state absorption transitions in this window. Here, we develop a class of lanthanide-doped imaging probes that harness an energy-looping mechanism that facilitates excitation at NIR-II wavelengths, such as 1064 nm, that are resonant with excited-state absorption transitions but not ground-state absorption. Using computational methods and combinatorial screening, we have identified Tm(3+)-doped NaYF4 nanoparticles as efficient looping systems that emit at 800 nm under continuous-wave excitation at 1064 nm. Using this benign excitation with standard confocal microscopy, energy-looping nanoparticles (ELNPs) are imaged in cultured mammalian cells and through brain tissue without autofluorescence. The 1 mm imaging depths and 2 μm feature sizes are comparable to those demonstrated by state-of-the-art multiphoton techniques, illustrating that ELNPs are a promising class of NIR probes for high-fidelity visualization in cells and tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
In vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Gee, S., Ellwood, I., Patel, T., Luongo, F., Deisseroth, K., & Sohal, V. S. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.5835-11.2012 · Cited by 214
Self-citation
Cited by
Advances in highly doped upconversion nanoparticles
Wen, S., Zhou, J., Zheng, K., Bednarkiewicz, A., Liu, X., & Jin, D. (2018) · Nature Communications · doi:10.1038/s41467-018-04813-5 · Cited by 1,116
Optical nano-agents in the second near-infrared window for biomedical applications
Cai, Y., Wei, Z., Song, C., Tang, C., Han, W., & Dong, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00494c · Cited by 603
Liu, L., Wang, S., Zhao, B., Pei, P., Fan, Y., Li, X., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201802889 · Cited by 345
Xu, J., Gulzar, A., Yang, P., Bi, H., Yang, D., Gai, S., He, F., Lin, J., Xing, B., & Jin, D. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.11.014 · Cited by 310
Constitutional Isomerization Enables Bright NIR‐II AIEgen for Brain‐Inflammation Imaging
Liu, S., Chen, C., Li, Y., Zhang, H., Liu, J., Wang, R., Wong, S. T. H., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908125 · Cited by 267
Metadata
- Authors
- Levy, E. S., Tajon, C. A., Bischof, T. S., Iafrati, J., Fernandez-Bravo, A., Garfield, D. J., Chamanzar, M., Maharbiz, M. M., Sohal, V. S., Schuck, P. J., Cohen, B. E., & Chan, E. M.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-09-07
- Volume
- 10
- Issue
- 9
- Pages
- 8423-8433
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2512613115
- Cited by
- 172
- References
- 4
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.