The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
An Enzyme-Free Signal Amplification Technique for Ultrasensitive Colorimetric Assay of Disease Biomarkers
Open accessAbstract
Enzyme-based colorimetric assays have been widely used in research laboratories and clinical diagnosis for decades. Nevertheless, as constrained by the performance of enzymes, their detection sensitivity has not been substantially improved in recent years, which inhibits many critical applications such as early detection of cancers. In this work, we demonstrate an enzyme-free signal amplification technique, based on gold vesicles encapsulated with Pd–Ir nanoparticles as peroxidase mimics, for colorimetric assay of disease biomarkers with significantly enhanced sensitivity. This technique overcomes the intrinsic limitations of enzymes, thanks to the superior catalytic efficiency of peroxidase mimics and the efficient loading and release of these mimics. Using human prostate surface antigen as a model biomarker, we demonstrated that the enzyme-free assay could reach a limit of detection at the femtogram/mL level, which is over 10 3 -fold lower than that of conventional enzyme-based assay when the same antibodies and similar procedure were used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
In vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201
Armbruster, D. A., Tillman, M. D., & Hubbs, L. M. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.7.1233 · Cited by 483
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes (II)
Wu, J., Wang, X., Wang, Q., Lou, Z., Li, S., Zhu, Y., Qin, L., & Wei, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00457a · Cited by 4,108
Nanozymes: Activity origin, catalytic mechanism, and biological application
Yang, W., Yang, X., Zhu, L., Chu, H., Li, X., & Xu, W. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214170 · Cited by 470
Versatile Types of Organic/Inorganic Nanohybrids: From Strategic Design to Biomedical Applications
Zhao, N., Yan, L., Zhao, X., Chen, X., Li, A., Zheng, D., Zhou, X., Dai, X., & Xu, F.-J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00401 · Cited by 429
Metal-Polydopamine Framework: An Innovative Signal-Generation Tag for Colorimetric Immunoassay
Ren, R., Cai, G., Yu, Z., Zeng, Y., & Tang, D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03538 · Cited by 359
Electrochemical biosensors for the detection of lung cancer biomarkers: A review
Khanmohammadi, A., Aghaie, A., Vahedi, E., Qazvini, A., Ghanei, M., Afkhami, A., Hajian, A., & Bagheri, H. (2020) · Talanta · doi:10.1016/j.talanta.2019.120251 · Cited by 358
Metadata
- Authors
- Ye, H., Yang, K., Tao, J., Liu, Y., Zhang, Q., Habibi, S., Nie, Z., & Xia, X.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-02-03
- Volume
- 11
- Issue
- 2
- Pages
- 2052-2059
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2582958454
- Cited by
- 185
- References
- 3
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.