The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Fully Stretchable Textile Triboelectric Nanogenerator with Knitted Fabric Structures
Abstract
Harvesting human-motion energy for power-integrated wearable electronics could be a promising way to extend the battery-operation time of small low-power-consumption electronics such as various sensors. For this purpose, a fully stretchable triboelectric nanogenerator (S-TENG) that has been fabricated with knitted fabrics and has been integrated with the directly available materials and techniques of the textile industry is introduced. This device has been adapted to cloth movement and can generate electricity under compression and stretching. We investigated plain-, double-, and rib-fabric structures and analyzed their potentials for textile-based energy harvesting. The superior stretchable property of the rib-knitted fabric contributed to a dramatic enhancement of the triboelectric power-generation performance owing to the increased contact surface. The present study shows that, under stretching motions of up to 30%, the S-TENG generates a maximum voltage and a current of 23.50 V and 1.05 μA, respectively, depending on the fabric structures. Under compressions at 3.3 Hz, the S-TENG generated a constant average root-mean square power of up to 60 μW. The results of this work show the feasibility of a cloth-integrated and industrial-ready TENG for the harvesting of energy from human biomechanical movements in cloth and garments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in triboelectric nanogenerators as a new energy technology and self-powered sensors
Wang, Z. L., Chen, J., & Lin, L. (2015) · Energy & Environmental Science · doi:10.1039/c5ee01532d · Cited by 2,174
Yang, Y., Zhang, H., Lin, Z.-H., Zhou, Y. S., Jing, Q., Su, Y., Yang, J., Chen, J., Hu, C., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn403838y · Cited by 798
Sustainably powering wearable electronics solely by biomechanical energy
Wang, J., Li, S., Yi, F., Zi, Y., Lin, J., Wang, X., Xu, Y., & Wang, Z. L. (2016) · Nature Communications · doi:10.1038/ncomms12744 · Cited by 648 · cited 1×
“performances as the maximum voltage and current peaks.(2,25,41) However, it is difficult to”
Background
Cited by
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Recent progress of triboelectric nanogenerators: From fundamental theory to practical applications
Luo, J., & Wang, Z. L. (2020) · EcoMat · doi:10.1002/eom2.12059 · Cited by 451
Li, D., Yadav, A., Zhou, H., Roy, K., Thanasekaran, P., & Lee, C. (2024) · Global Challenges · doi:10.1002/gch2.202300244 · Cited by 437
Chen, C., Chen, L., Wu, Z., Guo, H., Yu, W., Du, Z., & Wang, Z. L. (2020) · Materials Today · doi:10.1016/j.mattod.2019.10.025 · Cited by 355
Transcatheter Self‐Powered Ultrasensitive Endocardial Pressure Sensor
Liu, Z., Ma, Y., Ouyang, H., Shi, B., Li, N., Jiang, D., Xie, F., Qu, D., Zou, Y., Huang, Y., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807560 · Cited by 308
Metadata
- Authors
- Kwak, S. S., Kim, H., Seung, W., Kim, J., Hinchet, R., & Kim, S.-W.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-10-09
- Volume
- 11
- Issue
- 11
- Pages
- 10733-10741
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2762914507
- Cited by
- 242
- References
- 3
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully Stretchable Textile Triboelectric Nanogenerator with Knitted Fabric Structures. https://app.cochat.ai/papers/10.1021/acsnano.7b05203
- The paper
- Kwak, S. S., Kim, H., Seung, W., Kim, J., Hinchet, R., & Kim, S.-W. (2017). Fully Stretchable Textile Triboelectric Nanogenerator with Knitted Fabric Structures. ACS Nano. https://doi.org/10.1021/acsnano.7b05203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.