Nanoparticle-Enhanced Plasmonic Biosensor for Digital Biomarker Detection in a Microarray
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Nanoplasmonic devices have become a paradigm for biomolecular detection enabled by enhanced light-matter interactions in the fields from biological and pharmaceutical research to medical diagnostics and global health. In this work, we present a bright-field imaging plasmonic biosensor that allows visualization of single subwavelength gold nanoparticles (NPs) on large-area gold nanohole arrays (Au-NHAs). The sensor generates image heatmaps that reveal the locations of single NPs as high-contrast spikes, enabling the detection of individual NP-labeled molecules. We implemented the proposed method in a sandwich immunoassay for the detection of biotinylated bovine serum albumin (bBSA) and human C-reactive protein (CRP), a clinical biomarker of acute inflammatory diseases. Our method can detect 10 pg/mL of bBSA and 27 pg/mL CRP in 2 h, which is at least 4 orders of magnitude lower than the clinically relevant concentrations. Our sensitive and rapid detection approach paired with the robust large-area plasmonic sensor chips, which are fabricated using scalable and low-cost manufacturing, provides a powerful platform for multiplexed biomarker detection in various settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rosuvastatin to Prevent Vascular Events in Men and Women with Elevated C-Reactive Protein
Ridker, P. M., Danielson, E., Fonseca, F. A. H., Genest, J., Gotto, A. M., Kastelein, J. J. P., Koenig, W., Libby, P., Lorenzatti, A. J., MacFadyen, J. G., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0807646 · Cited by 6,674
C-Reactive Protein, Interleukin 6, and Risk of Developing Type 2 Diabetes Mellitus
Pradhan, A. D. (2001) · JAMA · doi:10.1001/jama.286.3.327 · Cited by 4,433
C-Reactive Protein Levels and Outcomes after Statin Therapy
Ridker, P. M., Cannon, C. P., Morrow, D., Rifai, N., Rose, L. M., McCabe, C. H., Pfeffer, M. A., & Braunwald, E. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042378 · Cited by 2,292
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Black, S., Kushner, I., & Samols, D. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.r400025200 · Cited by 1,844
Associations of elevated interleukin-6 and C-reactive protein levels with mortality in the elderly
Harris, T. B., Ferrucci, L., Tracy, R. P., Corti, M. C., Wacholder, S., Ettinger, W. H., Heimovitz, H., Cohen, H. J., & Wallace, R. (1999) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)00066-2 · Cited by 1,488
Cited by
Leveraging of MEMS Technologies for Optical Metamaterials Applications
Ren, Z., Chang, Y., Ma, Y., Shih, K., Dong, B., & Lee, C. (2020) · Advanced Optical Materials · doi:10.1002/adom.201900653 · Cited by 211
Dielectric nanohole array metasurface for high-resolution near-field sensing and imaging
Conteduca, D., Barth, I., Pitruzzello, G., Reardon, C. P., Martins, E. R., & Krauss, T. F. (2021) · Nature Communications · doi:10.1038/s41467-021-23357-9 · Cited by 207
Metadata
- Authors
- Belushkin, A., Yesilkoy, F., & Altug, H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-05-01
- Volume
- 12
- Issue
- 5
- Pages
- 4453-4461
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2802957172
- Cited by
- 159
- References
- 6
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoparticle-Enhanced Plasmonic Biosensor for Digital Biomarker Detection in a Microarray. https://app.cochat.ai/papers/10.1021/acsnano.8b00519
- The paper
- Belushkin, A., Yesilkoy, F., & Altug, H. (2018). Nanoparticle-Enhanced Plasmonic Biosensor for Digital Biomarker Detection in a Microarray. ACS Nano. https://doi.org/10.1021/acsnano.8b00519
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.