Expansion Stimulated Emission Depletion Microscopy (ExSTED)
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Stimulated emission depletion (STED) microscopy is routinely used to resolve the ultrastructure of cells with a ∼10-fold higher resolution compared to diffraction limited imaging. While STED microscopy is based on preparing the excited state of fluorescent probes with light, the recently developed expansion microscopy (ExM) provides subdiffraction resolution by physically enlarging the sample before microscopy. The expansion of the fixed cells by cross-linking and swelling of hydrogels easily enlarges the sample ∼4-fold and hence increases the effective optical resolution by this factor. To overcome the current limits of these complementary approaches, we combined ExM with STED (ExSTED) and demonstrated an increase in resolution of up to 30-fold compared to conventional microscopy (<10 nm lateral and ∼50 nm isotropic). While the increase in resolution is straightforward, we found that high-fidelity labeling via multi-epitopes is required to obtain emitter densities that allow ultrastructural details with ExSTED to be resolved. Our work provides a robust template for super-resolution microscopy of entire cells in the ten nanometer range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
Chen, F., Tillberg, P. W., & Boyden, E. S. (2015) · Science · doi:10.1126/science.1260088 · Cited by 1,501
Evaluation of fluorophores for optimal performance in localization-based super-resolution imaging
Dempsey, G. T., Vaughan, J. C., Chen, K. H., Bates, M., & Zhuang, X. (2011) · Nature Methods · doi:10.1038/nmeth.1768 · Cited by 1,369
Actin, Spectrin, and Associated Proteins Form a Periodic Cytoskeletal Structure in Axons
Xu, K., Zhong, G., & Zhuang, X. (2013) · Science · doi:10.1126/science.1232251 · Cited by 1,246
Nanometer resolution imaging and tracking of fluorescent molecules with minimal photon fluxes
Balzarotti, F., Eilers, Y., Gwosch, K. C., Gynnå, A. H., Westphal, V., Stefani, F. D., Elf, J., & Hell, S. W. (2017) · Science · doi:10.1126/science.aak9913 · Cited by 1,225
Cited by
Imaging cellular ultrastructures using expansion microscopy (U-ExM)
Gambarotto, D., Zwettler, F. U., Le Guennec, M., Schmidt-Cernohorska, M., Fortun, D., Borgers, S., Heine, J., Schloetel, J.-G., Reuss, M., Unser, M., et al. (2019) · Nature Methods · doi:10.1038/s41592-018-0238-1 · Cited by 564
Expansion microscopy: principles and uses in biological research
Wassie, A. T., Zhao, Y., & Boyden, E. S. (2019) · Nature Methods · doi:10.1038/s41592-018-0219-4 · Cited by 468
Hua, X.-W., Bao, Y.-W., Zeng, J., & Wu, F.-G. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b09590 · Cited by 207
Zwettler, F. U., Reinhard, S., Gambarotto, D., Bell, T. D. M., Hamel, V., Guichard, P., & Sauer, M. (2020) · Nature Communications · doi:10.1038/s41467-020-17086-8 · Cited by 189
The cell biologist's guide to super-resolution microscopy
Jacquemet, G., Carisey, A. F., Hamidi, H., Henriques, R., & Leterrier, C. (2020) · Journal of Cell Science · doi:10.1242/jcs.240713 · Cited by 171
One-step nanoscale expansion microscopy reveals individual protein shapes
Shaib, A. H., Chouaib, A. A., Chowdhury, R., Altendorf, J., Mihaylov, D., Zhang, C., Krah, D., Imani, V., Spencer, R. K. W., Georgiev, S. V., et al. (2025) · Nature Biotechnology · doi:10.1038/s41587-024-02431-9 · Cited by 104
Quantitative mapping of dense microtubule arrays in mammalian neurons
Katrukha, E. A., Jurriens, D., Salas Pastene, D. M., & Kapitein, L. C. (2021) · eLife · doi:10.7554/elife.67925 · Cited by 74
Metadata
- Authors
- Gao, M., Maraspini, R., Beutel, O., Zehtabian, A., Eickholt, B., Honigmann, A., & Ewers, H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-04-19
- Volume
- 12
- Issue
- 5
- Pages
- 4178-4185
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2789364354
- Cited by
- 180
- References
- 39
- FWCI
- 11.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.