CoChat

Ultrasensitive Virion Immunoassay Platform with Dual-Modality Based on a Multifunctional Aggregation-Induced Emission Luminogen

Xiong, Ling-Hong, He, Xuewen, Zhao, Zheng, Kwok, Ryan T. K., Xiong, Yu, Gao, Peng Fei, Yang, Fan, Huang, Yalan, Sung, Herman H.-Y., Williams, Ian D., Lam, Jacky W. Y., Cheng, Jinquan, Zhang, Renli, Tang, Ben Zhong · 2018 · ACS Nano
Cited by 123

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Sensitive and accurate detection of highly contagious virus is urgently demanded for disease diagnosis and treatment. Herein, based on a multifunctional aggregation-induced emission luminogen (AIEgen), a dual-modality readout immunoassay platform for ultrasensitive detection of viruses has been successfully demonstrated. The platform is relied on virions immuno-bridged enzymatic hydrolysis of AIEgen, accompanying with the in situ formation of highly emissive AIE aggregates and shelling of silver on gold nanoparticles. As a result, robust turn-on fluorescence and naked-eye discernible plasmonic colorimetry composed dual-signal is achieved. By further taking advantage of effective immunomagnetic enrichment, EV71 virions, as an example, can be specifically detected with a limit of detection down to 1.4 copies/μL under fluorescence modality. Additionally, semiquantitative discerning of EV71 virions is realized in a broad range from 1.3 × 10 3 to 2.5 × 10 6 copies/μL with the naked eye. Most importantly, EV71 virions in 24 real clinical samples are successfully diagnosed with 100% accuracy. Comparing to the gold standard polymerase chain reaction (PCR) assay, our immunoassay platform do not need complicated sample pretreatment and expensive instruments. This dual-modality strategy builds a good capability for both colorimetry based convenient preliminary screening and fluorescence based accurate diagnosis of suspect infections in virus-stricken areas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.8b05270

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 123

Metadata

Authors
Xiong, L.-H., He, X., Zhao, Z., Kwok, R. T. K., Xiong, Y., Gao, P. F., Yang, F., Huang, Y., Sung, H. H.-Y., Williams, I. D., Lam, J. W. Y., Cheng, J., Zhang, R., & Tang, B. Z.
Venue
ACS Nano
Published
2018-08-27
Volume
12
Issue
9
Pages
9549-9557
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2889210807
Cited by
123
References
2
FWCI
5.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasensitive Virion Immunoassay Platform with Dual-Modality Based on a Multifunctional Aggregation-Induced Emission Luminogen. https://app.cochat.ai/papers/10.1021/acsnano.8b05270
The paper
Xiong, L.-H., He, X., Zhao, Z., Kwok, R. T. K., Xiong, Y., Gao, P. F., Yang, F., Huang, Y., Sung, H. H.-Y., Williams, I. D., Lam, J. W. Y., Cheng, J., Zhang, R., & Tang, B. Z. (2018). Ultrasensitive Virion Immunoassay Platform with Dual-Modality Based on a Multifunctional Aggregation-Induced Emission Luminogen. ACS Nano. https://doi.org/10.1021/acsnano.8b05270

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.