The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
N- and B-Codoped Graphene: A Strong Candidate To Replace Natural Peroxidase in Sensitive and Selective Bioassays
Abstract
The work describes a carbon-based peroxidase mimic, N- and B-codoped reduced graphene oxide (NB-rGO), which shows high peroxidase-like activity without oxidase-like activity and has a catalytic efficiency nearly 1000-fold higher than that of undoped rGO. The high catalytic activity of NB-rGO is explained by density functional theory by calculating Gibbs free energy change during the peroxide decomposition reaction. Acetylcholine and C-reactive protein are successfully quantified with high sensitivity and selectivity, which were comparable to or better than those obtained using natural peroxidase. Furthermore, NB-rGO, which does not have oxidase-like activity, is proven to have higher sensitivity toward acetylcholine than Pt nanoparticles having oxidase-like activity. This work will facilitate studies on development, theoretical analysis for rational design, and bioassay applications of enzyme mimics based on nanomaterials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Pearson, T. A., Mensah, G. A., Alexander, R. W., Anderson, J. L., Cannon, R. O., Criqui, M., Fadl, Y. Y., Fortmann, S. P., Hong, Y., Myers, G. L., et al. (2003) · Circulation · doi:10.1161/01.cir.0000052939.59093.45 · Cited by 6,401
Cited by
Structure and activity of nanozymes: Inspirations for de novo design of nanozymes
Wang, Z., Zhang, R., Yan, X., & Fan, K. (2020) · Materials Today · doi:10.1016/j.mattod.2020.08.020 · Cited by 898
Coordination Number Regulation of Molybdenum Single-Atom Nanozyme Peroxidase-like Specificity
Wang, Y., Jia, G., Cui, X., Zhao, X., Zhang, Q., Gu, L., Zheng, L., Li, L. H., Wu, Q., Singh, D. J., et al. (2021) · Chem · doi:10.1016/j.chempr.2020.10.023 · Cited by 417
Defect Engineering in Nanocatalysts: From Design and Synthesis to Applications
Muhammad, P., Zada, A., Rashid, J., Hanif, S., Gao, Y., Li, C., Li, Y., Fan, K., & Wang, Y. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202314686 · Cited by 350
Nanozyme Sensor Arrays Based on Heteroatom-Doped Graphene for Detecting Pesticides
Zhu, Y., Wu, J., Han, L., Wang, X., Li, W., Guo, H., & Wei, H. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05110 · Cited by 308
Wu, Y., Wu, J., Jiao, L., Xu, W., Wang, H., Wei, X., Gu, W., Ren, G., Zhang, N., Zhang, Q., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05437 · Cited by 307
Liu, C., Fan, W., Cheng, W., Gu, Y., Chen, Y., Zhou, W., Yu, X., Chen, M., Zhu, M., Fan, K., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202213856 · Cited by 295
Carbon-based nanozymes: Design, catalytic mechanism, and bioapplication
Sun, Y., Xu, B., Pan, X., Wang, H., Wu, Q., Li, S., Jiang, B., & Liu, H. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214896 · Cited by 287
Chen, Q., Zhang, X., Li, S., Tan, J., Xu, C., & Huang, Y. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.125130 · Cited by 275
Defect engineering in nanozymes
Wu, Y., Xu, W., Jiao, L., Tang, Y., Chen, Y., Gu, W., & Zhu, C. (2022) · Materials Today · doi:10.1016/j.mattod.2021.10.032 · Cited by 269
Kim, M. S., Lee, J., Kim, H. S., Cho, A., Shim, K. H., Le, T. N., An, S. S. A., Han, J. W., Kim, M. I., & Lee, J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201905410 · Cited by 263
Self-citation
Metadata
- Authors
- Kim, M. S., Cho, S., Joo, S. H., Lee, J., Kwak, S. K., Kim, M. I., & Lee, J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-03-25
- Volume
- 13
- Issue
- 4
- Pages
- 4312-4321
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2924311868
- Cited by
- 201
- References
- 2
- FWCI
- 10.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.