CoChat

RamanFormer: A Transformer-Based Quantification Approach for Raman Mixture Components

Open access

The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.

Abstract

Raman spectroscopy is a noninvasive technique to identify materials by their unique molecular vibrational fingerprints. However, distinguishing and quantifying components in mixtures present challenges due to overlapping spectra, especially when components share similar features. This study presents "RamanFormer", a transformer-based model designed to enhance the analysis of Raman spectroscopy data. By effectively managing sequential data and integrating self-attention mechanisms, RamanFormer identifies and quantifies components in chemical mixtures with high precision, achieving a mean absolute error of 1.4% and a root mean squared error of 1.6%, significantly outperforming traditional methods such as least squares, MLP, VGG11, and ResNet50. Tested extensively on binary and ternary mixtures under varying conditions, including noise levels with a signal-to-noise ratio of up to 10 dB, RamanFormer proves to be a robust tool, improving the reliability of material identification and broadening the application of Raman spectroscopy in fields, such as material science, forensics, and biomedical diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsomega.3c09247

Cites

64 of 64 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Diagram illustrates the sequential composition of layers in the proposed model for robust spectral analysis and precise component ratio prediction. Here, N stands for the number of samples (eq 5).
Figure 1 Diagram illustrates the sequential composition of layers in the proposed model for robust spectral analysis and precise component ratio prediction. Here, N stands for the number of samples (eq 5).CC BY-NC-ND · PubMed Central
Figure 2 Raman spectra presented here showcase a specific ternary mixture and its individual components: (a) methanol (M), (b) isopropyl alcohol (IPA), and (c) ethanolamine (E) and (d) Raman spectrum of a ternary mixture composed of M, IPA, and E. The respective ratios of these components in the mixture are methanol at 78.75%, isopropyl alcohol at 8.75%, and ethanolamine at 12.50%.
Figure 2 Raman spectra presented here showcase a specific ternary mixture and its individual components: (a) methanol (M), (b) isopropyl alcohol (IPA), and (c) ethanolamine (E) and (d) Raman spectrum of a ternary mixture composed of M, IPA, and E. The respective ratios of these components in the mixture are methanol at 78.75%, isopropyl alcohol at 8.75%, and ethanolamine at 12.50%.CC BY-NC-ND · PubMed Central
Figure 3 Prediction errors of methanol (M), isopropyl alcohol (IPA), and ethanolamine (E) in the mixtures of (a) isopropyl alcohol and ethanolamine, (b) methanol and ethanolamine, and (c) methanol and isopropyl alcohol. Actual mixture percentages of M, IPA, and E are specified under each bar plot, respectively.
Figure 3 Prediction errors of methanol (M), isopropyl alcohol (IPA), and ethanolamine (E) in the mixtures of (a) isopropyl alcohol and ethanolamine, (b) methanol and ethanolamine, and (c) methanol and isopropyl alcohol. Actual mixture percentages of M, IPA, and E are specified under each bar plot, respectively.CC BY-NC-ND · PubMed Central
Figure 4 Prediction errors of methanol (M), isopropyl alcohol (IPA), and ethanolamine (E) in the ternary mixtures. Actual mixture percentages of M, IPA, and E are specified under each bar plot, respectively.
Figure 4 Prediction errors of methanol (M), isopropyl alcohol (IPA), and ethanolamine (E) in the ternary mixtures. Actual mixture percentages of M, IPA, and E are specified under each bar plot, respectively.CC BY-NC-ND · PubMed Central
Figure 5 Prediction errors of methanol (M), isopropyl alcohol (IPA), and ethanolamine (E) in the binary mixtures of challenging scenarios, where one chemical is dominant and the other chemical is present in very low amounts.
Figure 5 Prediction errors of methanol (M), isopropyl alcohol (IPA), and ethanolamine (E) in the binary mixtures of challenging scenarios, where one chemical is dominant and the other chemical is present in very low amounts.CC BY-NC-ND · PubMed Central
Figure 6 Demonstration that when exposed to a noisy training set characterized by diverse signal-to-noise ratio (SNR) values, the model exhibits the capability to achieve convergence even with a signal-to-noise ratio (SNR) of 0 dB, though with a somewhat higher error. Training instances are augmented with additive Gaussian noise as in eq 6, while evaluation of the error is conducted on the clean, untouched test data.
Figure 6 Demonstration that when exposed to a noisy training set characterized by diverse signal-to-noise ratio (SNR) values, the model exhibits the capability to achieve convergence even with a signal-to-noise ratio (SNR) of 0 dB, though with a somewhat higher error. Training instances are augmented with additive Gaussian noise as in eq 6, while evaluation of the error is conducted on the clean, untouched test data.CC BY-NC-ND · PubMed Central
Figure 7 Evaluation of the RamanFormer model’s performance across different levels of additive noise, as measured by varying signal-to-noise ratios (SNR), showcasing its durability against noise in test data. Notably, RamanFormer remains effective against noise up to a 10 dB SNR threshold, after which error rates start to increase gradually.
Figure 7 Evaluation of the RamanFormer model’s performance across different levels of additive noise, as measured by varying signal-to-noise ratios (SNR), showcasing its durability against noise in test data. Notably, RamanFormer remains effective against noise up to a 10 dB SNR threshold, after which error rates start to increase gradually.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Goodfellow I., 2014, Advances in neural information processing systems, 27

Cited by

See all 32

Metadata

Authors
Koyun, O. C., Keser, R. K., Şahin, S. O., Bulut, D., Yorulmaz, M., Yücesoy, V., & Töreyin, B. U.
Affiliations
  • Istanbul Technical University (TR)
  • Aselsan (Turkey) (TR)
  • Signal Processing for Computational Intelligence Research Group (SP4CING), Informatics Institute, Istanbul Technical University, 34469 Istanbul, Turkey
Corresponding author
Koyun, Onur Can
Venue
ACS Omega
Published
2024-05-23
Volume
9
Issue
22
Pages
23241-23251
ISSN
2470-1343 (ISSN-L)
OpenAlex
W4398234105
Cited by
32
References
64
Citations by year
2026: 17 · 2025: 13 · 2024: 2
FWCI
5.49
Type
journal article
Language
en
Open access
Locations
  • ACS Omega (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Istanbul Technical University Academic Open Archive (Istanbul Technical University) (submittedVersion)
Funders
ASELSAN
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Social Sciences › Arts and Humanities › Archeology (arts and humanities) › Cultural Heritage Materials Analysis
Keywords
Raman spectroscopy, transformer models, self-attention, component quantification, spectral unmixing, overlapping spectra, binary and ternary mixtures, material identification, noise robustness

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.