The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Fully Flexible MXene-based Gas Sensor on Paper for Highly Sensitive Room-Temperature Nitrogen Dioxide Detection
Abstract
Flexible chemiresistive gas sensors have attracted growing interest due to their capability in real-time and rapid detection of gas. However, the performance of gas sensors has long been hindered by the poor charge transfer ability between the conventional metal electrode and gas sensing semiconductors. Herein, for the first time, a fully flexible paper-based gas sensor integrated with the Ti 3 C 2 T x -MXene nonmetallic electrode and the Ti 3 C 2 T x /WS 2 gas sensing film was designed to form Ohmic contact and Schottky heterojunction in a single gas sensing channel. Ti 3 C 2 T x /WS 2 has outstanding physical and chemical properties for both Ti 3 C 2 T x and WS 2 nanoflakes, showing high conductivity, effective charge transfer, and abundant active sites for gas sensing. The response of the gas sensor to NO 2 (1 ppm) at room temperature is 15.2%, which is about 3.2 and 76.0 times as high as that of the Au interdigital electrode integrated with the Ti 3 C 2 T x /WS 2 sensor (4.8%) and the MXene electrode integrated with the Ti 3 C 2 T x sensor (0.2%), respectively. Besides, this design performed at a limit of detection with 11.0 ppb NO 2 gas and displayed excellent stability under high humidities. Based on first-principles density functional theory calculation results, the improvement of the gas sensing performance can be mainly attributed to the heterojunction regulation effect, work function matching, and suppressing metal-induced gap states. This work provides a new approach for the design of flexible gas sensors on paper with MXene-based conductive electrodes and gas sensing materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fast and robust algorithm for Bader decomposition of charge density
Henkelman, G., Arnaldsson, A., & Jónsson, H. (2006) · Computational Materials Science · doi:10.1016/j.commatsci.2005.04.010 · Cited by 10,723
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Self-powered ultra-flexible electronics via nano-grating-patterned organic photovoltaics
Park, S., Heo, S. W., Lee, W., Inoue, D., Jiang, Z., Yu, K., Jinno, H., Hashizume, D., Sekino, M., Yokota, T., et al. (2018) · Nature · doi:10.1038/s41586-018-0536-x · Cited by 1,068
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Cited by
2D Materials in Flexible Electronics: Recent Advances and Future Prospectives
Katiyar, A. K., Hoang, A. T., Xu, D., Hong, J., Kim, B. J., Ji, S., & Ahn, J.-H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00302 · Cited by 363
Metadata
- Authors
- Quan, W., Shi, J., Luo, H., Fan, C., Lv, W., Chen, X., Zeng, M., Yang, J., Hu, N., Su, Y., Wei, H., & Yang, Z.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2023-01-13
- Volume
- 8
- Issue
- 1
- Pages
- 103-113
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W4315797514
- Cited by
- 243
- References
- 4
- FWCI
- 17.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully Flexible MXene-based Gas Sensor on Paper for Highly Sensitive Room-Temperature Nitrogen Dioxide Detection. https://app.cochat.ai/papers/10.1021/acssensors.2c01748
- The paper
- Quan, W., Shi, J., Luo, H., Fan, C., Lv, W., Chen, X., Zeng, M., Yang, J., Hu, N., Su, Y., Wei, H., & Yang, Z. (2023). Fully Flexible MXene-based Gas Sensor on Paper for Highly Sensitive Room-Temperature Nitrogen Dioxide Detection. ACS Sensors. https://doi.org/10.1021/acssensors.2c01748
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.