CoChat

3D Printed “Earable” Smart Devices for Real-Time Detection of Core Body Temperature

Open access

The DOI matches its Crossref record; 39 of the 40 references it cites were found in a registry or an index.

Abstract

Real-time detection of basic physiological parameters such as blood pressure and heart rate is an important target in wearable smart devices for healthcare. Among these, the core body temperature is one of the most important basic medical indicators of fever, insomnia, fatigue, metabolic functionality, and depression. However, traditional wearable temperature sensors are based upon the measurement of skin temperature, which can vary dramatically from the true core body temperature. Here, we demonstrate a three-dimensional (3D) printed wearable “earable” smart device that is designed to be worn on the ear to track core body temperature from the tympanic membrane (i.e., ear drum) based on an infrared sensor. The device is fully integrated with data processing circuits and a wireless module for standalone functionality. Using this smart earable device, we demonstrate that the core body temperature can be accurately monitored regardless of the environment and activity of the user. In addition, a microphone and actuator are also integrated so that the device can also function as a bone conduction hearing aid. Using 3D printing as the fabrication method enables the device to be customized for the wearer for more personalized healthcare. This smart device provides an important advance in realizing personalized health care by enabling real-time monitoring of one of the most important medical parameters, core body temperature, employed in preliminary medical screening tests.

Overview

Integrity signals

Registry

Crossref · 10.1021/acssensors.7b00247

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 39 references

Cited by

Items 101–154 of 154

Metadata

Authors
Ota, H., Chao, M., Gao, Y., Wu, E., Tai, L.-C., Chen, K., Matsuoka, Y., Iwai, K., Fahad, H. M., Gao, W., Nyein, H. Y. Y., Lin, L., & Javey, A.
Affiliations
  • Lawrence Berkeley National Laboratory (US)
  • University of California, Berkeley (US)
Corresponding author
Javey, Ali
Venue
ACS Sensors
Published
2017-07-19
Volume
2
Issue
7
Pages
990-997
ISSN
2379-3694 (ISSN-L)
OpenAlex
W2738311417
Cited by
154
References
40
Citations by year
2026: 13 · 2025: 18 · 2024: 14 · 2023: 19 · 2022: 26 · 2021: 18 · 2020: 19 · 2019: 14 · 2018: 11 · 2017: 1
FWCI
5.55
Type
journal article
Language
en
Open access
Locations
  • ACS Sensors (publishedVersion, other-oa)
  • PubMed (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion)
  • Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
Funders
  • National Science Foundation (NA)
  • China Scholarship Council (201406250097)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
core body temperature monitoring, tympanic membrane, infrared temperature sensing, wearable smart devices, bone conduction hearing aids, personalized healthcare, wireless data transmission, fever detection, health screening

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.