CoChat

Surface-Enhanced Raman Scattering-Based Odor Compass: Locating Multiple Chemical Sources and Pathogens

Open access
Thrift, William John, Cabuslay, Antony, Laird, Andrew Benjamin, Ranjbar, Saba, Hochbaum, Allon I., Ragan, Regina · 2019 · ACS Sensors
Cited by 55

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Abstract Olfaction is important for identifying and avoiding toxic substances in living systems. Many efforts have been made to realize artificial olfaction systems that reflect the capacity of biological systems. A sophisticated example of an artificial olfaction device is the odor compass which uses chemical sensor data to identify odor source direction. Successful odor compass designs often rely on plume-based detection and mobile robots, where active, mechanical motion of the sensor platform is employed. Passive, diffusion-based odor compasses remain elusive as detection of low analyte concentrations and quantification of small concentration gradients from within the sensor platform are necessary. Further, simultaneously identifying multiple odor sources using an odor compass remains an ongoing challenge, especially for similar analytes. Here, we show that surface-enhanced Raman scattering (SERS) sensors overcome these challenges, and we present the first SERS odor compass. Using a grid array of SERS sensors, machine learning analysis enables reliable identification of multiple odor sources arising from diffusion of analytes from one or two localized sources. Specifically, convolutional neural network and support vector machine classifier models achieve over 90% accuracy for a multiple odor source problem. This system is then used to identify the location of an Escherichia coli biofilm via its complex signature of volatile organic compounds. Thus, the fabricated SERS chemical sensors have the needed limit of detection and quantification for diffusion-based odor compasses. Solving the multiple odor source problem with a passive platform opens a path toward an Internet of things approach to monitor toxic gases and indoor pathogens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acssensors.9b00809

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Thrift, W. J., Cabuslay, A., Laird, A. B., Ranjbar, S., Hochbaum, A. I., & Ragan, R.
Venue
ACS Sensors
Published
2019-08-16
Volume
4
Issue
9
Pages
2311-2319
ISSN
2379-3694 (ISSN-L)
OpenAlex
W2968663739
Cited by
55
References
3
FWCI
1.58
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.