The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
High-Frequency, Magnetic-Field-Responsive Drug Release from Magnetic Nanoparticle/Organic Hybrid Based on Hyperthermic Effect
Abstract
Magnetic nanoparticles (MNPs) generate heat when a high-frequency magnetic field (HFMF) is applied to them. Induction heat is useful not only for hyperthermia treatment but also as a driving force for drug-release. beta-Cyclodextrin (CD) can act as drug container because of its inclusion properties. Drugs incorporated in the CD can thus be released through the use of induction heating, or hyperthermic effects, by applying a HFMF. In this study, we have synthesized folic acid (FA) and CD-functionalized superparamagnetic iron oxide nanoparticles, FA-CD-SPIONs, by chemically modifying SPIONs derived from iron(III) allylacetylacetonate. FA is well-known as a targeting ligand for breast cancer tumor and endows the SPIONs with cancer-targeting capability. Immobilization of FA and CD on spinel iron oxide nanoparticles was confirmed by Fourier transform IR (FTIR) and X-ray photoelectron spectroscopy (XPS). The FA-CD-SPIONs have a hydrodynamic diameter of 12.4 nm and prolonged stability in water. They are superparamagnetic with a magnetization of 51 emu g(-1) at 16 kOe. They generate heat when an alternating current (AC) magnetic field is applied to them and have a specific absorption rate (SAR) of 132 W g(-1) at 230 kHz and 100 Oe. Induction heating triggers drug release from the CD cavity on the particle - a behavior that is controlled by switching the HFMF on and off. The FA-CD-SPIONs are noncytotoxic for cells. Thus, FA-CD-SPIONs can serve as a novel device for performing drug delivery and hyperthermia simultaneously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Multifunctional Magnetic Nanoparticles: Design, Synthesis, and Biomedical Applications
Gao, J., Gu, H., & Xu, B. (2009) · Accounts of Chemical Research · doi:10.1021/ar9000026 · Cited by 1,907
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Iron Oxide Nanoparticles for Magnetically-Guided and Magnetically-Responsive Drug Delivery
Estelrich, J., Escribano, E., Queralt, J., & Busquets, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16048070 · Cited by 532
Nanoparticle-mediated Hyperthermia in Cancer Therapy
Chatterjee, D. K., Diagaradjane, P., & Krishnan, S. (2011) · Therapeutic Delivery · doi:10.4155/tde.11.72 · Cited by 417
Metadata
- Authors
- Hayashi, K., Ono, K., Suzuki, H., Sawada, M., Moriya, M., Sakamoto, W., & Yogo, T.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-06-22
- Volume
- 2
- Issue
- 7
- Pages
- 1903-1911
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2069228719
- Cited by
- 254
- References
- 2
- FWCI
- 5.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.