The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Zwitterionic Sulfobetaine-Grafted Poly(vinylidene fluoride) Membrane with Highly Effective Blood Compatibility via Atmospheric Plasma-Induced Surface Copolymerization
Abstract
Development of nonfouling membranes to prevent nonspecific protein adsorption and platelet adhesion is critical for many biomedical applications. It is always a challenge to control the surface graft copolymerization of a highly polar monomer from the highly hydrophobic surface of a fluoropolymer membrane. In this work, the blood compatibility of poly(vinylidene fluoride) (PVDF) membranes with surface-grafted electrically neutral zwitterionic poly(sulfobetaine methacrylate) (PSBMA), from atmospheric plasma-induced surface copolymerization, was studied. The effect of surface composition and graft morphology, electrical neutrality, hydrophilicity and hydration capability on blood compatibility of the membranes were determined. Blood compatibility of the zwitterionic PVDF membranes was systematically evaluated by plasma protein adsorption, platelet adhesion, plasma-clotting time, and blood cell hemolysis. It was found that the nonfouling nature and hydration capability of grafted PSBMA polymers can be effectively controlled by regulating the grafting coverage and charge balance of the PSBMA layer on the PVDF membrane surface. Even a slight charge bias in the grafted zwitterionic PSBMA layer can induce electrostatic interactions between proteins and the membrane surfaces, leading to surface protein adsorption, platelet activation, plasma clotting and blood cell hemolysis. Thus, the optimized PSBMA surface graft layer in overall charge neutrality has a high hydration capability and the best antifouling, anticoagulant, and antihemolytic activities when comes into contact with human blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Surface Modifications for Antifouling Membranes
Rana, D., & Matsuura, T. (2010) · Chemical Reviews · doi:10.1021/cr800208y · Cited by 2,161
Jiang, S., & Cao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200901407 · Cited by 2,027
Poly(Ethylene Glycol) Chemistry: Biotechnical and Biomedical Applications
(1992) · Springer eBooks · doi:10.1007/978-1-4899-0703-5 · Cited by 1,420
Preparation of Phospholipid Polylners and Their Properties as Polymer Hydrogel Membranes
Ishihara, K., Ueda, T., & Nakabayashi, N. (1990) · Polymer Journal · doi:10.1295/polymj.22.355 · Cited by 1,078
Zwitterionic SAMs that Resist Nonspecific Adsorption of Protein from Aqueous Buffer
Holmlin, R. E., Chen, X., Chapman, R. G., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la0015258 · Cited by 891
Superlow Fouling Sulfobetaine and Carboxybetaine Polymers on Glass Slides
Zhang, Z., Chao, T., Chen, S., & Jiang, S. (2006) · Langmuir · doi:10.1021/la062175d · Cited by 673
Zhang, Z., Chen, S., Chang, Y., & Jiang, S. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057266i · Cited by 539
Self-citationBlood compatibility of surfaces with superlow protein adsorption
Zhang, Z., Zhang, M., Chen, S., Horbett, T. A., Ratner, B. D., & Jiang, S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.07.039 · Cited by 462
An New Avenue to Nonfouling Materials
Chen, S., & Jiang, S. (2008) · Advanced Materials · doi:10.1002/adma.200701164 · Cited by 406
Cited by
Ren, X., Feng, Y., Guo, J., Wang, H., Li, Q., Yang, J., Hao, X., Lv, J., Ma, N., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00483c · Cited by 573
Polymeric Delivery of Therapeutic Nucleic Acids
Kumar, R., Santa Chalarca, C. F., Bockman, M. R., Bruggen, C. V., Grimme, C. J., Dalal, R. J., Hanson, M. G., Hexum, J. K., & Reineke, T. M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00997 · Cited by 365
Yue, W.-W., Li, H.-J., Xiang, T., Qin, H., Sun, S.-D., & Zhao, C.-S. (2013) · Journal of Membrane Science · doi:10.1016/j.memsci.2013.06.029 · Cited by 299
Blood compatible materials: state of the art
Liu, X., Yuan, L., Li, D., Tang, Z., Wang, Y., Chen, G., Chen, H., & Brash, J. L. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00881b · Cited by 288
The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity
Brash, J. L., Horbett, T. A., Latour, R. A., & Tengvall, P. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.022 · Cited by 282
Metadata
- Authors
- Chang, Y., Chang, W.-J., Shih, Y.-J., Wei, T.-C., & Hsiue, G.-H.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-03-21
- Volume
- 3
- Issue
- 4
- Pages
- 1228-1237
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W1985094436
- Cited by
- 325
- References
- 31
- FWCI
- 11.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Zwitterionic Sulfobetaine-Grafted Poly(vinylidene fluoride) Membrane with Highly Effective Blood Compatibility via Atmospheric Plasma-Induced Surface Copolymerization. https://app.cochat.ai/papers/10.1021/am200055k
- The paper
- Chang, Y., Chang, W.-J., Shih, Y.-J., Wei, T.-C., & Hsiue, G.-H. (2011). Zwitterionic Sulfobetaine-Grafted Poly(vinylidene fluoride) Membrane with Highly Effective Blood Compatibility via Atmospheric Plasma-Induced Surface Copolymerization. ACS Applied Materials & Interfaces. https://doi.org/10.1021/am200055k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.