The DOI matches its Crossref record; 221 of the 221 references it cites were found in a registry or an index.
Blood compatible materials: state of the art
Abstract
Approaches to thromboresistant materials are discussed including passivation; incorporation and/or release of anticoagulants, antiplatelet agents, thrombolytic agents; and mimicry of the vascular endothelium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isolation of Putative Progenitor Endothelial Cells for Angiogenesis
Asahara, T., Murohara, T., Sullivan, A., Silver, M., van der Zee, R., Li, T., Witzenbichler, B., Schatteman, G., & Isner, J. M. (1997) · Science · doi:10.1126/science.275.5302.964 · Cited by 8,725
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Jiang, S., & Cao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200901407 · Cited by 2,027
New Approaches to Nanofabrication: Molding, Printing, and Other Techniques
Gates, B. D., Xu, Q., Stewart, M., Ryan, D., Willson, C. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr030076o · Cited by 2,020
Self-Assembled Organic Monolayers: Model Systems for Studying Adsorption of Proteins at Aurfaces
Prime, K. L., & Whitesides, G. M. (1991) · Science · doi:10.1126/science.252.5009.1164 · Cited by 1,831
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Walkey, C. D., & Chan, W. C. W. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15233e · Cited by 1,758
Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials
Chen, S., Li, L., Zhao, C., & Zheng, J. (2010) · Polymer · doi:10.1016/j.polymer.2010.08.022 · Cited by 1,677
Weitz, J. I. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709043371007 · Cited by 1,533
Protein—surface interactions in the presence of polyethylene oxide
Jeon, S. I., Lee, J. H., Andrade, J. D., & De Gennes, P. G. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90043-8 · Cited by 1,523
Cited by
The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity
Brash, J. L., Horbett, T. A., Latour, R. A., & Tengvall, P. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.022 · Cited by 282
Self-citationSuperhydrophobic Blood‐Repellent Surfaces
Jokinen, V., Kankuri, E., Hoshian, S., Franssila, S., & Ras, R. H. A. (2018) · Advanced Materials · doi:10.1002/adma.201705104 · Cited by 257
Metadata
- Authors
- Liu, X., Yuan, L., Li, D., Tang, Z., Wang, Y., Chen, G., Chen, H., & Brash, J. L.
- Venue
- J. Mater. Chem. B
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 2
- Issue
- 35
- Pages
- 5718-5738
- ISSN
- 2050-750X (ISSN-L)
- 2050-7518
- OpenAlex
- W2152921610
- Cited by
- 288
- References
- 221
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood compatible materials: state of the art. https://app.cochat.ai/papers/10.1039/c4tb00881b
- The paper
- Liu, X., Yuan, L., Li, D., Tang, Z., Wang, Y., Chen, G., Chen, H., & Brash, J. L. (2014). Blood compatible materials: state of the art. J. Mater. Chem. B. https://doi.org/10.1039/c4tb00881b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.